6.4.6 Configuring Cell Handover
You can configure handover parameters for a cell. The
HandOver tab allows you to add, modify, or delete the fields
of the Handover tab for cell. Cell lock is not required for
modifying cell parameters. Cell lock is required to delete a
cell. In addition, handover parameters are added in cell
locked state. If you do not add the handover parameters
then cell unlock fails.
In addition to the values provided for a field in the HandOver
tab, the consistency condition should match in order to
change the values of handover fields. For example, if you
want to change the value of WindowSize RxLev field (refer
Table 12”) then these two conditions should match:
The value of WindowSize RxLev should be between 1
and 10.
The windowSizeRxLevH windowSizeRxLevP and
windowSizeRxLevH windowSizeNcell
If both the above conditions match then only you can
change the value of WindowSize RxtLev field.
Follow the below steps to add handover:
1. Open the BSS node in the modify mode.
2. Expand RadioConfig, expand LAC, click LAC :<IP
address>, and click CELL :<IP address>.
3. Click the HandOver tab. Refer “Error! Reference source
not found.”.
4. Click Add.
The Configuration – Add Row dialog box appears.