User Manual

SECTION TSM 443
PAGE 8 OF 8
ISSUE C
VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA 50613 USA
© 3/2013 Viking Pump Inc.
All rights reserved
TECHNICAL SERVICE MANUAL
WARRANTY
Viking warrants all products manufactured by it to be
free from defects in workmanship or material for a
period of one (1) year from date of startup, provided
that in no event shall this warranty extend more than
eighteen (18) months from the date of shipment from
Viking. The warranty period for Universal Seal series
pumps ONLY (Universal Seal models listed below) is
three (3) years from date of startup, provided that in
no event shall this warranty extend more than forty-two
(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE
LIABLE UNDER THIS WARRANTY OR OTHERWISE
FOR SPECIAL, INCIDENTAL, INDIRECT,
CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY
KIND, INCLUDING, BUT NOT LIMITED TO, LOST
OR UNREALIZED SALES, REVENUES, PROFITS,
INCOME, COST SAVINGS OR BUSINESS, LOST OR
UNREALIZED CONTRACTS, LOSS OF GOODWILL,
DAMAGE TO REPUTATION, LOSS OF PROPERTY,
LOSS OF INFORMATION OR DATA, LOSS OF
PRODUCTION, DOWNTIME, OR INCREASED
COSTS, IN CONNECTION WITH ANY PRODUCT,
EVEN IF VIKING HAS BEEN ADVISED OR PLACED
ON NOTICE OF THE POSSIBILITY OF SUCH
DAMAGES AND NOTWITHSTANDING THE FAILURE
OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE
AND EXCLUSIVE WARRANTY AND SHALL BE IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, ALL WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE AND
NON-INFRINGEMENT ALL OF WHICH OTHER
WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.
DANGER !
BE SURE VALVE AND SYSTEM ARE FREE
OF LP-GAS.
1. Remove the valve cap.
2. Measure and record the length of extension of the
adjusting screw.
3. Loosen the locknut and back out the adjusting screw
until the spring pressure is released.
4. Remove the bonnet, spring guide, spring(s) and poppet
from the valve body. Clean and inspect all parts for wear
or damage and replace as necessary.
Follow the procedure outlined under Disassembly.
Remember to replace gaskets, and re-set and lock adjusting
screw.
In ordering parts for relief valve on head, always be sure
to give Model and Serial Number of pump as it appears on
nameplate and the name of the part wanted. When ordering
springs, be sure to give the pressure setting desired. If valve
is removed for repairs, be sure to replace in same position.
The return to tank valve should be on the discharge side of
the pump.
ASSEMBLY
IMPORTANT
DANGER !
Before opening any Viking pump liquid
chamber (pumping chamber, reservoir, relief
valve adjusting cap fitting etc.) Be sure:
1. That any pressure in the chamber has
been completely vented through the
suction or discharge lines or other
appropriate openings or connections.
2. That the driving means (motor, turbine,
engine, etc.) has been “locked out” or
made non- operational so that it cannot
be started while work is being done on
pump.
3. That you know what liquid the pump
has been handling and the precautions
necessary to safely handle the liquid.
Obtain a material safety data sheet
(MSDS) for the liquid to be sure these
precautions are understood.
Failure to follow above listed precautionary
measures may result in serious injury or
death.
DISASSEMBLY
VIKING BRACKET MOUNTED LP-GAS PUMPS
SERIES 200-G AND 260-G
SIZES K, KK, L, LQ, LL