Owner's manual
SECTIONTSM 630.4 ISSUE D PAGE7 OF 10
1. Inputpowerforthecontrollermustbe240VAC,
singlephase,60Hzor220VAC,singlephase,50Hz.
2. Controllerterminals
a. 18to12AWGwiresizeforheatersandcontroller.
Useappropriatethermocouplewireforthermocouple
and application.
b. Torqueto7.0lb-in(0.8Nm)
c. Wirestriplength0.30in(7.6mm).
3. RelayinputterminalsforusewithNsizepumponly
(terminals7-16)
a. 24to16AWGwiresize
b. Torqueto4.4lb-in(0.5Nm)
c. Wirestriplengthof0.22in(5.5mm)
4. RelaylineandloadterminalsforusewithNsizepump
only(terminals1-6)
a. Willaccept18to8AWGwiresize
b. Torqueto12lb-in(1.4Nm)
c. Wirestriplength0.25in(6.35mm)
d. Retorqueafter48hourstominimizewirecoldflow
e. Retorqueterminalsevery3to6months
f. GroundterminalusespadeterminalforNo.8screw,
with upturned lugs
g. Attachgroundingwiretogroundingscrew(#6)
5. Maintainelectricalisolationbetweenthermocoupleanalog
input1(terminalsS1andR1),anydigitalinputs-outputs,
andprocessoutputs1and2(terminalsL1,K1andL2,
K2,respectively)topreventgroundloops.
6. Topreventinjuryanddamagetothecontroller,donot
connect wires to unused terminals.
7. Thewiresfortheheatcartridgescanbejoinedtogetherin
ajunctionbox,andasinglewirefromthejunctionboxcan
be connected to the controller.
8. The wiring diagram is only valid for standard type J
thermocouplesandcontrollerssuppliedfromVikingPump.
9. Forinformationonthelocationandinstallationoftheheat
cartridgesandthermocouple,pleaseseetheTSMfor
your specific pump. The thermocouple will require a fitting
adapterwhichisincludedwiththecontrollerkitinorderto
mount to the pump.
NOTES:
FIGURE 4 - CONTROLLER TERMINAL LOCATIONS FIGURE 5 - RELAY TERMINAL LOCATIONS
(FOR N SIZE PUMP ONLY)
TABLE 1 - CONTROLLER TERMINAL DESCRIPTIONS
TABLE 2 - RELAY TERMINAL DESCRIPTIONS
(FOR N SIZE PUMP ONLY)
Slot A Slot C
L1
NormallyOpen
(NotReadyLight)
98
PowerInput;AC;Fused
(Controller)
K1
Common
(ReadyLight/PumpInterlock)
99
Common(Controller)
J1
NormallyClosed
(ReadyLight)
CF
NotUsed
L2
PowerOutput;Fused
(HeatCartridges)
CD
NotUsed
K2
Common
(HeatCartridges)
CE
NotUsed
T1
NotUsed
B5
NotUsed
S1
NegativeThermocoupleLead
(Usuallyredwireused)
D6
NotUsed
R1
PositiveThermocoupleLead
D5
NotUsed
RelayTerminalDenitions
1
NotUsed
2
PowerInput;AC;Fused(FromPowerSource)
3
Common
4
NotUsed
5
Heater
6
Heater
7
PowerInput(FromController)
8
Common
9 - 16
NotUsed