Viking Installation Guide Designer Series Built-In 18” H.
NOTE: IF INSTALLING HOOD WITH WARMING SHELF PANEL, INSTALL WARMING SHELF PANEL FIRST. WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, RANGEHOODS MUST BE INSTALLED WITH THE VENTILATORS THAT ARE SPECIFIED ON THEIR CARTON INDICATING SUITABILITY WITH THIS MODEL. OTHER VENTILATORS CANNOT BE SUBSTITUTED. IMPORTANT - PLEASE READ AND FOLLOW •Before beginning, please read these instructions completely and carefully.
BASIC SPECIFICATIONS INTERIOR AND EXTERIOR POWER HOODS RECOM. DESCRIPTION CFM1 NUMBER OF HALOGEN LIGHTS (int.-interior; ext-exterior FILTERS 120VAC/60Hz SPACERS MAX. AMPS3 (Interior/Exterior) 18” H. Wall 30”W.* 36”W.* 42”W.* 48”W. 2 2 2 3 300 int/600 int./1200 int./900 ext./1200 ext. 300 int/600 int./1200 int./900 ext./1200 ext. 600 int./1200 int./900 ext./1200 ext. 1200 int./1200 ext./1500 ext. 2 2 3 3 0 1 0 0 2.4/4.6/6.6/6.6/3.9 2.4/4.6/6.6/6.6/3.9 4.6/6.6/6.6/4.0 7.0/4.3/5.
HEIGHT OF HOOD The bottom of the hood should be 30” (76.2 cm) min. to 36” (91.4 cm) max. above the countertop. This would typically result in the bottom of the hood being 66” (167.6 cm) to 72” (182.9 cm) above the floor. For best performance, it is recommended that the bottom of the hood be 30” (76.2 cm) to 33” (83.8 cm) above the countertop. These dimensions provide for safe and efficient operation of the hood. Clearance Dimensions 18” (45.7 cm) 30” (76.2 cm) Min. 36” (91.4 cm) Max.
PREPARING FOR HOOD INSTALLATION Plan where the ductwork will be located. See pages 8-11 for rough-in dimensions. Install proper-sized duct work, and roof or wall cap for the type of blower you are using. Recommended hood locations for the most common installations are shown on page 2. Exterior Blower Adjust your measurements for various heights of ceilings, soffits, cabinets, or ranges/rangetops. 10” Round Roof Cap Roof Cap Duct 10” Round duct 7” Round Duct 12” (30.5 cm) 12” (30.
INSTALLING ROUGH-IN PLATE AND CONNECTING DUCT - INTERNAL POWER (Also see instructions supplied with ventilator kit) 1. Attach rough-in plate to studs in the inside, top of hood with four (4) #10-24 nuts provided. 2. Connect ductwork using supplied transition and damper (transition and damper are part of rough-in plate on some models). Use duct tape to make all joints secure and air tight. In some installations, it is easier to attach transition to plate before attaching plate to hood. 3.
INSTALLING THE VENTILATORS VIV300 or VIV600 - Interior-Power Ventilator Kit (300 or 600 CFM) (also see instructions supplied with ventilator kit) 1. Make sure barrel nuts and wing nut are engaged halfway onto threaded stud. 2. Lift ventilator into canopy - may be easier to turn ventilator side ways to lift into canopy then rotate into mounting position. 3. Lift ventilator allowing barrel nuts to come through large end of keyhole opening. Rough-in 4.
INSTALLING ROUGH-IN PLATE AND CONNECTING DUCT -EXTERNAL POWER (Also see instructions supplied with ventilator kit) 1. Run 10” round steel ductwork, from exterior blower to the installationlocation. For best performance, use the straightest possible duct run and the fewest number of elbows. Tape all joints. 2. Run 120 VAC electrical power cable from service panel and from remote blower to installation location. 3. Remove wiring box cover. Remove knockouts from the wiring box.
ROOF CUTOUT ROOF INSTALLATION EXTERIOR-POWER VENTILATOR 203/4” (52.7 cm) VEV/dev900-Exterior Power Ventilator Kit (900CFM) (also see instructions supplied with ventilator kit) 1. Locate the blower on the rear slope of the roof. Place it in a location to minimize duct run. The location should be free of obstacles (T.V. leads, electrical lines, etc.). Bear in mind, if the blower top is level with the roof peak, it will not be seen from the street.
WALL INSTALLATION EXTERIOR-POWER VENTILATOR WALL CUTOUT VEV900-Exterior-Power Ventilator Kit (900CFM) 1. Choose a position on the outside wall. Min. 24” (61.0 cm from ground may vary depending on local codes or location. Make sure that no wall studs, pipes or wires run through the opening area. 2. Drill a guide hole at the center of the opening area. 3. From the outside, use the guide hole as a starting point to lay out the installation. A. Use a T-square to measure 103/4” (27.
ROOF INSTALLATION EXTERIOR-POWER VENTILATOR 11/4” (3.2 cm) dia. hole ROOF CUTOUT B VEV1200-Exterior Power Ventilator (1200 CFM) (also see instructions supplied with ventilator kit) REMOVE 1. Locate the blower on the rear slope of the roof. S HINGLES Place it in a location to minimize duct run. The 12 11/16” location should be free of obstacles (T.V. leads, (32.2 cm) electrical lines, etc.). Bear in mind, if the blower top is level with the roof peak, it will not be seen from the street.
WALL INSTALLATION EXTERIOR-POWER VENTILATOR WALL CUTOUT B VEV1200-Exterior Power Ventilator Kit (1200 CFM) 1. Choose a position on the outside wall. Min. 24” (61.0 cm 11/4” (3.2 cm) from ground may vary depending on local codes or location. dia. hole Make sure that no wall studs, pipes or wires run through 11/16 14 the opening area. 2. From inside, mark and drill a guide hole at the center of (37.3 cm) the opening area. 3.
EXTERIOR VENTILATOR DIMENSIONS DEV1200 DEV1500 VEV900 Opening for wiring 10” Dia. A 203/4” (52.7 cm) 3” (7. 6c m) 1 29 /2” (74.9 cm) 5” (12.7 cm) 281/4” (71.8 cm) 1 10 /8” 25.7 cm 14 13/16” (37.6 cm) 241/2” (62.2 cm) 151/2” (39.4 cm) 6 1/4 ” (15.9 cm) Opening for wiring 14” (35.6 cm) 3 1/2” (8.9 cm) 243/4” (62.9 cm) 10” (25.4 cm) Dia. 1 22 /8” (56.2 cm) 11 13/16” (30.0 cm) B Flashing 43/4” (12.1 cm) DEV1200 Flashing DEV1500 WIRING DIAGRAM EXTERIOR VENTILATOR 13 A B 18” 22” (45.
WALL HOOD DIMENSIONS tall traditional - ledgeless/ tall traditional - ledge Transition VIV1200 Only 9” (22.9 cm) 1 1/2” (3.8 cm) 1” (2.5 cm) 12” (30.5 cm) 1 1/2” (3.8 cm) 7/8” (2.2 cm) 18” (45.7 cm) 18” (45.7 cm) 24” (61.0 cm) 24” (61.0 cm) SIDE VIEW EXTERNAL POWER SIDE VIEW INTERNAL POWER B 18 3/4” (47.6 cm) *NOTE: VIV600 - 7” VIV1200 - 10” 8 1/4” (20.9 cm) 5 15/16” (15.1 cm) 6 7/16” (16.4 cm) 4 5/8” (11.7 cm) 9 1/8” (23.2 cm) 3” (7.6 cm) 9 3/4” (24.8 cm) 24” (61.
23 15/16” (60.8 cm) 23 15/16” (60.8 cm) 83/16” 5/8” (1.6 cm) (20.7 cm) 515/16” (15.1cm) 51/2” 65/8” (16.8 cm) 120 V 83/8” (14.0 cm) 120 V 3” (7.62 cm) 21/2”(6.35 cm) 91/4” 91/2” (23.5 cm) (24.1 cm) (21.3 cm) 183/4” (47.6 cm) 9 3/4” (25.4 cm) dia. cutout 47 7/8” (121.6 cm) 47 7/8” (121.6 cm) 48” W. INTERNAL POWER - VIV1200 48” W. EXTERNAL POWER - VEV1200 or VEV1500 WIRING DIAGRAM DESIGNER SERIES BUILT-IN HOODS REFER ONLY TO FEATURES EQUIPPED WITH THIS UNIT.
VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.