Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.
Table of Contents Warnings & Important Information_____________________________________________________ 3 Dimensions _________________________________________________________________________ 6 Specifications _______________________________________________________________________ 7 Cutout Dimensions (Professional/Custom) ______________________________________________ 8 Cabinet Information (Professional) _____________________________________________________ 9 Cabinet Information (Professional w/flush mount tr
IMPORTANT–Please Read and Follow! WARNING WARNING ELECTRICAL SHOCK HAZARD TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock. Use two or more people to move and install appliance.
Dimensions Specifications 30” Professional Description VCWB301/Standard Mount Overall width 9 -5 (23 /16 .6 ” cm ) Overall depth from rear 3 (76 0” .2 cm ) 30” Custom 2 .5 c 9- (245/8 .4 ” cm ) m) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To rear edge of side trim: 22-3/16” (56.4 cm) To front of door: 24-1/32” (61.0 cm) To end of handle bracket: 27” (68.6 cm) 23-13/16” (60.5 cm) To front of door: 24-1/32” (61.0 cm) To end of handle bracket: 27” (68.6 cm) 29-5/8” (75.
Cutout Dimensions (Professional/Custom) 2” x 4” Mounting Board [1-1/2” (3.8 cm) x 3-1/2” (8.9 cm)] Attached to anti-tip mounting bracket Note: If unit is installed deeper than 24” (61.0 cm), then shim behind anti-tip bracket thickness by the same amount Cabinet Information (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/16” (5.2 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room.
Cabinet Information (Professional) Cabinet Information (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 2-1/16” (5.2 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room. Wall Wall TOP VIEW 1-13/16” (4.6 cm) space if 24” (61.0 cm) standard cabinet depth is used 3/4” (1.9 cm) full end panel 24” (61.0 cm) standard cabinet depth TOP VIEW 1-13/16” (4.6 cm) space if 24” (61.
Cabinet Information Cabinet Information Professional models with Flush Mount Trim fit “flush” in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2” (6.3 cm) handle depth. Professional models with Flush Mount Trim fit “flush” in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except 2-1/2” (6.3 cm) handle depth. (Professional with Flush Mount Trim) (Professional with Flush Mount Trim) Wall 1” (2.5 cm) space if 25” (63.
Cabinet Information Cabinet Information (Professional with Flush Mount Trim) (Custom Panel) Custom Panel models, [3/4” (1.9 cm) thick panels and custom handles locally supplied], fit flush in 25” (63.5 cm) deep (countertop depth) cabinet openings with no protrusion into room except custom handles. Wall Wall 3/4” (1.9 cm) space if 24” (61.0 cm) standard cabinet depth is used 1/4” (0.6 cm) 3/4” (1.9 cm) full end panel 24” (61.0 cm) standard cabinet depth TOP VIEW TOP VIEW 25” (63.
Cabinet Information (Custom Panel) Custom Panel models, [3/4” (1.9 cm) thick panels and custom handles locally supplied], fit flush in 25” (63.5 cm) deep (countertop depth) cabinet openings with no protrusion into room except custom handles. Cabinet Information Custom Panel models can be installed in standard 24” (61.0 cm) deep openings. However, the door faces and top ventilation grille will protrude 3/4” (1.9 cm) into the room, ideal for alignment with full overlay cabinet doors. 1/4” (0.
Custom Side Panel Dimensions (Professional - Standard Mount) 8” -3/ ) 22.0 cm (57 (Custom Panel/Professional with Flush Mount Trim) NOTE: Adding a 3/4” (1.9 cm) side panel adds an additional 3/4” (1.9 cm) to the overall width of the product for each side panel used. Requires side panel hardware kit (Kit model number SPHKDS). TOP VIEW 3/16” (0.5 cm) thick back filler panel Custom Side Panel Dimensions 3/4” (1.9 cm) thick end panel TOP VIEW Z-Bracket 1” (2.5 cm) 1/4” (0.6 cm) 4” -3/ ) 21.
Custom Door Panel Dimensions 5/16” (0.8 cm) 1-3/8” Pre-drill the holes in the panel per the panel dimension instructions. (See Panel Dimensions for proper hole locations.) 1-5/16” (3.3 cm) TOP VIEW Place the panel onto the door and using 1/2” (1.3 cm) #8 wood screws, attach the panel in 12 places. (2 at the top and bottom, 4 on each side) Note: The handle must be attached to the panel prior to installing the panel onto the door. See panel dimensions for proper attachment locations of the handles.
Custom Wood Facing Dimensions Custom Wood Facing Dimensions Each wine rack has a wood facing which can be removed. The facings can be stained, painted, or removed and replaced with alternative wood facings. Note: A scrap sample should be tested in the unit before attaching permanent changes to your wine cellar fronts. Some paints and/or stains can cause undesirable odors. SIDE VIEW Remove the wood facing by removing the four 1/4” (0.6 cm) hex head screws located on the inner edge of the wine rack.
General Information General Information Area Requirements • Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. • Assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances. (115 volt, 60-Hz, 15 amp, fused, electrical supply is required.
Home Security System Connection Securing Your Wine Cellar WARNING NOTE: Contact a qualified electrician or authorized agent from alarm company to connect your home security system to the wine cellar. Home security system connection must be hooked up before the unit is installed. 1. Remove the four mounting screws attaching the unit compartment cover to the cabinet. (2 per side) 2. Remove the grille louver assembly to access the black safety grille. 3. Turn power off. 4.
Securing Your Wine Cellar Kickplate Installation Before moving the wine cellar in place, confirm the finished dimensions, electrical location, minimum door and shelf clearances, and door panel instructions. 1. Position wine cellar in front of cutout. 2. Verify operation by plugging power cord in receptacle. Power switch will be shipped in the “ON” position and showroom switch will be in the “OFF” position.
Door Stop/Hinge Adjustment DOOR STOP Performance Checklist 1. Using a 3/16” Allen wrench, remove door stop pin located in bottom hinge. 2. The pin is factory set 110°. For 120° swing, move the pin to the utmost forward stop hole. For 90° swing, move the pin to the utmost rear stop hole. • Verify cabinet size. Installer’s information: • Verify electrical supply and water supply (if applicable).
Service & Registration If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor in your area. Have the following information readily available. • Model number • Serial number • Date purchased • Name of dealer from whom purchased Clearly describe the problem that you are having.
34 35