Natural Gas Conversion Kit - NATVGC - Installation Instructions

3
VGC/CVGC Orifice Locations
B
B
C
D
A
*Burner rates will be lowered by 4% per 1000 ft. above altitudes of 2000 ft.
When the conversion is completed, complete the enclosed conversion label and place it next to the rating
label. The rating label for your cooktop is located on the exterior bottom panel of the burner box in the right
rear corner.
PROPER LIGHTING AND SHUTDOWN INSTRUCTIONS
1. To ignite the surface burners, turn the knob counter clockwise to any position.
2. Upon ignition of the surface burner, turn the knob to the desired position, (HI, Med, or Low).
3. To shutdown the burner, turn knob clockwise to the OFF position.
4. In case of failure, shut the gas OFF using the installer supplied manual shut-off valve.
Burner NAT
Left Front (A) .079 (2.01mm) 044706-000
Left Rear (B .056 (1.42 mm) 044708-000
Center Rear (C) .060 (1.52 mm) PB040255
Center Front (C) .060 (1.52 mm) PB040255
Right Rear (E) .048 (1.22 mm) 044709-000
Right Front (D) .042 (1.07 mm) PB040274
Burner NAT
Left Front (A) .079 (2.01mm) 044706-000
Left Rear (B) .064 (1.63 mm) PB040255
Center (B)
.064 (1.63 mm) PB040255
Right Rear (C) .051 (1.30 mm) 044707-000
Right Front (D) .042 (1.07 mm) PB040274
Burner 30”W. Model Burner 36”W. Model
Left Front (A)
18,000 BTU NAT
(5.4 kW NAT)
Left Front (A)
18,000 BTU NAT
(5.4 kW NAT)
Left Rear (B)
12,000 BTU NAT
(3.6 kW NAT)
Left Rear (B)
10,000 BTU NAT
(3.0 kW LP)
Center (B)
12,000 BTU NAT
(3.6 kW NAT)
Center Rear (C
12,000 BTU NAT
(3.6 kW NAT)
Center Front (C)
12,000 BTU NAT
(3.6 kW NAT)
Right Rear (C)
8,000 NAT
(2.4 kW NAT)
Right Rear (E
8,000 NAT
(2.4 kW NAT)
Right Front (D)
6,000 BTU NAT
(1.8 kW NAT)
Right Front (D)
6,000 BTU NAT
(1.8 kW NAT)
VGC/CVGC530
VGSU/CVGSU530
VGC/CVGC536
VGSU/CVGSU536
B C E
D
CA