Owner's manual

AD6464M / AD128128M Rev. 5
2.5 Rear view
Figure 1: Rear view
The following service connectors can be found on the rear of the Modular AES/EBU Digital
Audio Router:
AC Mains A: AC mains power supply.
AC Mains B: AC mains power supply (if redundant PSU is installed).
Serial A1 and A2: RS-232 or RS-422 for external control protocols.
Serial B1 and B2: RS-232 or RS-422 for external control protocols (if redundant
SysCon is installed).
Ethernet A: 10/100Base-T Ethernet bus for external router control.
Ethernet B: 10/100Base-T Ethernet bus for external router control (if redundant
SysCon-SM is installed).
Serial GYDA A: RS-232 or RS-422 for external connection to GYDA-VX (if GYDA-VX is
installed).
Serial GYDA B: RS-232 or RS-422 for external connection to GYDA-VX (if redundant
GYDA-VX is installed).
Ethernet GYDA A: 10/100Base-T Ethernet bus for external connection to GYDA-VX
(if GYDA-VX is installed).
Ethernet GYDA B: 10/100Base-T Ethernet bus for external connection to GYDA-VX
(if redundant GYDA-VX is installed).
VIT 11: Synchronisation signal 1 (in/out). Blackburst/composite/tri-level sync
reference input with passive loop-through for vertical interval switching.
VIT 21: Synchronisation signal 2 (in/out). Blackburst/composite/tri-level sync
reference input with passive loop-through for vertical interval switching.
Power Alarm: Power fail alarm relay contacts. Separate contact pair for each PSU
module that is installed. Contact closes on power failure. See Chapter 2 for further
description.
SW 1: Configuration switch 1 (not in use).
SW 2: Configuration switch 2 (not in use).
network-electronics.com | 8