Specifications
Page 37
4.3.4 RTP30 Class 2 Hygienic Mechanical Seal.
Fig 20 Class 2 Hygienic Mechanical Seal.
Read the general procedures before proceeding, refer to section 4.3.1.
- Remove dome nuts (36), front cover (38), rotor retainers (35), rotors (41)
and front cover o-ring (39), see section 4.1.
- The seal can now be accessed for inspection.
- Remove o-ring (25), from the end of the shaft.
- Remove the rotary seal face assembly from the shaft.
- If required, remove the seal housing (67) from the rotorcase by releasing
the retaining nut (12), care should be taken as the stationary seal face
may still be installed.
- If required, extract the stationary face from the seal sleeve, exposing the
o-rings. Note that there is an anti-rotation device incorporated into the
rotorcase (not shown), when replacing the seal housing (67), alignment
between the seal sleeve and rotorcase must be achieved to prevent
rotation.
Note: Extreme care should be taken when carrying out these procedures
to ensure that the seal faces are not damaged. If seals are being refitted,
ensure that seal faces remain matched.
- Assembly is the reverse of the above procedure, ensure that all faces are
clean and free from damage.