Use and Care Manual / Installation Instructions

10
3. Fill one cup of water, and one EC
1000 PPM solution
4. Gently wash the TDS probe in the
water and dry on a cloth
5. Gently swish the probe in EC PPM solu-
tion and, while swishing the probe,
enter the calibration screen.
water
EC
PPM
water
EC
PPM
Fig. 1
Access the water reservoir
1. Remove the lower grow drawer to access the reservoir (Fig.1)
2. Locate the TDS sensor probe on the right side of the reservoir (Fig.2)
Fig. 2
TDS sensor (black)
6. To enter the TDS calibration screen press SETUP (A), SET RESERVOIR (B), TDS SENSOR(C), then CALIBRATE (D) and follow the
instructions on the screen. Continue to swish the probe in the solution for three minutes.
Calibration will take about three minutes to complete.
Press DONE (E) when complete.
START-UP (continued)
CALIBRATE THE TOTAL DISSOLVED SOLIDS (TDS) SENSOR (EC 1000 PPM solution required)
A
B
C
D
E
Continued on next page