Use and Care Manual / Installation Instructions

6
If necessary, contact a licensed electrician to install an appropriate 15 amp
electrical circuit with correct NEMA receptacle. Ensure that the plug is accessi-
ble after installation.
DO NOT use an extension cord.
 Place the cabinet on level ground so that the inside water ows evenly. Adjust the leveling legs so that they are on the
oor. If your oor is not level, adjust the legs so that the unit is level. NOTE: Unit must be level in order to function
properly.
 See CUTOUT DIMENSIONS ON NEXT PAGE
 Leave at least 19 inches (483 mm) at the front of the cabinet, so there is ample space for opening the doors and pulling
the drawers out.
INSTALLATION AND STARTUP
Installation procedures must be performed by a qualied technician with full
knowledge of all applicable electrical and plumbing codes. Failure could result
in personal injury and property damage.
Damage to unit due to being connected to the wrong voltage or phase is NOT
covered by warranty.
The ground prong of the power cord is part of a system designed to protect
you from electric shock in the event of internal damage.
DO NOT cut o the large round ground prong or twist a blade to t an exist-
ing receptacle.
CAUTION: Electrical Shock
Hazard
IMPORTANT:
Power cord is 6' long
IMPORTANT:
Not under warranty
WARNING:
Risk of personal injury
Due to varying water quality in dierent municipalities, make sure that your
facility water is ltered of sediment and chemicals before hooking up the ll
lines. Sediment from hard and/or softened water may eventually clog up the
pumps and lters.
IMPORTANT: FILTERED
WATER REQUIRED
LOCATION
 Connect city water supply and city drain to the 3/8” NPT female ttings at the back of the unit . Access to the
connections will be at the back of the cabinet. NOTE: This unit is to be installed with adequate backow protection
to comply with all applicable federal, state and local codes.
 City water connection must not be further than 10 feet from the cabinet and no higher than 6 feet from the
connections. A minimum of 35 PSI is required to feed the cabinet.
 Install the lights and diuser panels (instructions on page 20)
 The 120V electrical outlet should be within 6 feet of the cabinet. Do not use an extension cord. Connect to a properly
grounded outlet according the electrical specications for the cabinet. See page 3 for specications.
Pipes that have not been in regular use should be cleaned an ushed
with running water prior to connecting to cabinet
Make sure the water inlet hose and drain hose are not twisted, crushed,
entangled or leaking. Do not use connection hoses that have been used
previously for other appliances.
If the unit is built in to a wall or structure, make sure that it can
be easily moved for access to the back and side panels for
service and maintenance.
City DRAIN connection:
3/8” NPT female fitting
City FILL connection:
3/8” NPT female fitting
GROUNDING INSTRUCTIONS
This appliance is equipped with a cord having a grounding wire with a grounding plug which must be hard wired or
plugged into an outlet that is properly installed and grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current.
WARNING—Improper use of the grounding can result in a risk of electric shock. Consult a qualied electrician or ser-
vice agent if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is
properly grounded.
SAFETY PRECAUTIONS
LOCATION AND INSTALLATION