Operation Manual

0478 192 9803 B - EN
44
Unscrew the nut (1) from black connection
cable (2) using two A/F 8 spanners and
remove the screw (3), washer (4) and
nut (1).
Detach and remove the black connection
cable (2) from the battery negative (–)
terminal.
Detach cap (5). Unscrew the nut (1) of the
red connection cable (6) from the battery
positive (+) terminal using two A/F
8 spanners and remove. Remove the
screw (3), washer (4) and nut (1).
Remove the red connection cable (6) from
the battery positive (+) terminal.
Remove the battery if necessary.
Reattach screws, washers and nuts to
the battery negative (–) and positive (+)
terminals for safe keeping.
Close the battery compartment if
necessary. (Ö 13.14)
Connecting the battery:
Set battery down.
If necessary, remove the screws,
washers and nuts from the battery.
Attach the terminal connector of the red
connection cable (6) (+) to the battery
positive (+) terminal.
Insert the screw (3) through the bore in the
positive terminal and through the bore in
the connection cable. Fit the washer (4)
onto the screw (3) and screw on the
nut (1).
Tighten the connection to a torque of
4 - 5Nm using two A/F 8 spanners. Fit
cap (5) to completely cover the
connection.
Attach the terminal connector of the black
connection cable (2) (–) to the battery
negative (–) terminal.
Insert screw (3) through the bores in the
negative terminal and through the bore in
the connection cable. Fit the washer (4)
onto the screw (3) and screw on the
nut (1).
Tighten the connection to a torque of
4 - 5Nm using two A/F 8 spanners.
Insert the battery.
Removing the battery:
Disconnect the battery. (Ö 13.15)
Pull out the battery.
Inserting the battery:
Open the battery
compartment. (Ö 13.14)
Connect the battery. (Ö 13.15)
The charge condition should be
checked before installation.
If the battery voltage is lower than
11.5 V, recharge the battery using a
battery charger before installation.