Installation Instructions

7
Electrical Requirements
WARNING
ELECTRICAL SHOCK
HAZARD
To avoid the risk of electrical
shock, personal injury or death;
verify electrical power is turned off at the
breaker box until the range is installed and
ready to operate, installation by an
authorized installer only.
RVEWD
Max. amp
usage
450 watts
3.8 amps
Electrical Requirements
Check your national and local codes regarding
this unit. Hard wire direct with seperate
120V/15 amp minimum 2-wire wtih ground
circuit. Maximum amp usage.
Electrical Connection
Note: Use copper conductors ONLY!
Grounding Instructions
This appliance must be connected to a
grounded metal, permanent wiring system, or
an equipment-grounding conductor must be
run with the circuit conductors and connected
to the equipment-grounding terminal or lead
on the appliance.
With the appliance positioned in front of the
cabinet opening, connect wire leads extending
from the power supply to the terminal block of
the unit. Make sure the colored wires of the
terminal block are connected to the
corresponding colored wires extending from
the power supply.