30" min.
(76. 2 cm)
to
36" max.
(91.4 cm)
36"
(91.4 cm)
66" min.
(167.6 cm)
to
72" max.
(182.9 cm)
27"
(68.6 cm)
DIM « X »
+ 4-1/2"
(11.4 cm)
18"
(45.7 cm)
(VWHO/CVWHO 18”H. Outdoor Wall Hoods)
Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from
the elements as much as possible.
The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface. The hood
should be installed 4-1/2” (11.4 cm) plus the distance between the back trim and surface from the back
wall. (Note: There is a 3minimum clearance from the back trim to non-combustible surfaces, and a 24”
minimum to combustible surfaces.) This will require building the hood out from the wall. Any combustible
material used for this purpose must be covered with locally-supplied stainless steel. Viking also
recommends using a backsplash.
Clearance Dimensions