Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.
Table of Contents IMPORTANT—Please Read and Follow! Warnings & Important Information ____________________________________________________ 3 Professional Side-by-Side Dimensions & Specifications (Professional 42” & 48”) ________________________________ 6 Dimensions & Specifications (Professional 42” & 48” with flush mount trim) ____________8 Cutout Dimensions (42”) _________________________________________________________10 Anti-Tip Dimensions (42”) ________________________________________________________1
IMPORTANT—Please Read and Follow! IMPORTANT—Please Read and Follow! A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances. • The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. • Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below.
Dimensions Specifications (Side-By-Side) (Side-By-Side) 42” Side-By-Side 42” Side-By Side 41” (9.1 cm ) Overall width Overall height from bottom Overall depth from rear /2” 1–1cm) (104.1 cm) 3 –1 9 / 32” Description (3.8 42” (106.7 cm ) Cutout width Cutout height Cutout depth Electrical requirements 48” Side-By Side 9–5 / (23. 32” 3 cm ) 47” /2” 1–1cm) (119.4 cm) 3–19/ 3 (9.1 cm2” ) (3.8 48” (121.9 cm) 75–1 (192 5/16” . 9 cm ) 9–5 82 / (23. 32” 3 cm ) (21 –3/4” 0.2 min cm) .
Dimensions Specifications (Side-By-Side with flush mount trim) 42” Side-By-Side with Flush Mount Trim 42” Side-By-Side with Flush Mount Trim 41 ” 3 –1 9 / 32” (9.1 cm ) Description Overall height from bottom Overall depth from rear (3.8 42” (106.7 cm ) / (23. 32” 3 cm ) 47” /2” 1–1cm) (119.4 cm) 3–19/ 3 (9.1 cm2” ) cm) (3.8 48” (121.9 cm) 9–5 82 / (23. 32” 3 cm ) (21 –3/4” 0.2 min cm) . 84–to (21 1/16” 3.5 ma cm) x.
Cutout Dimensions Anti-Tip Dimensions (Side-By-Side) 42” Side-By-Side 42” Side-By-Side 24” ) cm (61.0 See An (Side-By-Side) Anti-Tip Location Electric Outlet Location ti-Tip b o ard ins tallatio n 6” (15.2 c 9” (22.9 Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) m) cm) 3” m) (7.6 c 9” (22.9 c m) 79 (201 –3/8” .6 to bo cm) min . m) m antiin ti open p board . & ing h eigh t (8.9 c2” m) anti- ttom of tip b oard 84 80 (204 –1/2” .6 to bocm) max . ttom a (213 –1/16” .
Cutout Dimensions Anti-Tip Dimensions (Side-By-Side) 48” Side-By-Side 48” Side-By-Side 24” ) .0 cm (61 See An ti-Tip b o ard ins (Side-By-Side) Anti-Tip Location Electric Outlet Location tallatio n 6” (15.2 c 9” (22.9 Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) m) cm) 3” ) m 9” (22.9 c (7.6 c m) 41” (104.1 cm ) 82 (210 –7/8” .5 c 79 (201 –3/8” .6 to bo cm) min . m) m antiin ti open p board .
Dimensions Specifications (Bottom-Freezer) 36” Bottom-Freezer 36” Bottom-Freezer 35” 3–19/ 32” (9.1 cm ) 36” (88.9 c m) /2” 1–1cm) 36” Bottom-Freezer with Flush Mount Trim 9–5/3 2 (23.3 c ” m) 35” 36” 3–19/ 32” (9.1 cm 5 (132 2” .1 cm ) (88.9 c m) /2” 1–1cm) (3.8 (91.5 c m) ) 2 (23.3 c ” m) 82–3/ (210.2 4” cm min. ) to 84–1/ VCBB Overall width 36” (91.5 cm) 82-3/4” (210.2 cm) min. to 84-1/16” (213.5 cm) max. To front edge of side trim: 22-3/16” (56.
Cutout Dimensions Anti-Tip Dimensions (Bottom-Freezer) 36” Bottom-Freezer 36” Bottom-Freezer 24” ) cm (61.0 See An ti-Tip b o ard ins (Bottom-Freezer) Anti-Tip Location Electric Outlet Location tallatio n 6” (15.2 c Two 2”x 4” Mounting Boards 3” (7.6 cm) x 3-1/2” (8.9 cm) m) 9” (22.9 cm) 9” 3” (22.9 c m) 79 (201 –3/8” .6 to bo cm) min . anti- ttom of tip b oard 82 (210 –7/8” .5 anti- cm) mi tip n. 80 (204 –1/2” .
Cabinet Information Cabinet Information (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 1-3/4” (4.4 cm) from the cabinet face. The handle protrudes an additional 2-1/2” (6.4 cm) into the room. (Professional) Professional models fit “semi-flush” in standard 24” (61.0 cm) deep cabinet openings. The door face protrudes 1-3/4” (4.4 cm) from the cabinet face. The handles protrude an additional 2-1/2” (6.4 cm) into the room.
Cabinet Information (Professional with Flush Mount Trim) Professional models with flush mount trim fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room. Cabinet Information (Professional with Flush Mount Trim) Professional models with flush mount trim fit flush in standard 24” (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2” (6.4 cm) into the room.
Custom Side Panel Dimensions (Professional) 3/16” (0.5 cm) Back filler panel 6” 7/1 ) - m 227.0 c Custom Side Panel Dimensions (Professional with Flush Mount Trim) 3/4” (1.9 cm) End panel Z-Bracket 1” (2.5 cm) 4” -3/ ) 21.2 cm 6”cm) .2 (15 1/4” 3/4” (0.6 cm) (1.9 cm) End panel (55 (5 5/32” (0.4 cm) 4” -3/ ) 21.2 cm ” /16) 2-7 cm (55 2 7.0 5 ( (2182-7 0.5 /8 cm ” )m in. (21 84-1to 3.5 /1 cm 6” )m ax .* (2182-7 0.5 /8 cm ” )m 8 in. (21 4-1to 3.5 /1 c m 6” )m ax .* (2182-7 0.
General Information General Information Area Requirements It is required that a separate circuit serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-type wall receptacle. Do not use an extension cord. Verify the following: • Unit can fit into residence and can be moved around corners and through doorways.
General Information Flush Mount Side Trim Installation (sold separately) TIP OVER HAZARD • Most of the unit’s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury.
Hinge Adjustment 6 5 Front of unit 10b 10a 2 2 3” 1 1 Remove four side screws and remove unit top. 3 Loosen the four hinge screws. Adjust door. Retighten four hinge screws. 8a 7 Carefully move unit until semi flush with cabinet (depending on unit). Place unit within 3” of being flush with cabinets. NOTE: To avoid cabinet damage, place cardboard between cabinets and unit. When moving unit, do not crimp, kink or crush water supply line.
Door Stop Adjustment 15 (Side-by-Side) 20 16 21 1 1 Screw Wall 90˚ 110˚ 120˚ 3 2x4 Attach positive secure self-tapping bolts to 2x4 using a 22” extension. Lift unit off rollers to desired height and level unit using a 5/16” head wrench. NOTE: DO NOT use an electric device. Overtightening can cause damage. 2 2 Refrigerator 17 Open refrigerator door so door stop and shoulder screw are accessible. NOTE: Shoulder screw should be in 110˚ door opening position.
Water Filter Installation (Side-by-Side with Dispenser) Water Filter System Specification and Performance Data Sheet 25 24 This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration of less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.
Final Installation 28 Performance Checklist 29 Replace top air grille. Using an 8” magnetic nut driver, replace the two 1/4” screws. 31 30 Replace the center grille louver. Open door. Display should flash. 32 □ Verify cabinet size. □ Align/square door(s). □ Verify electrical supply and water supply (if applicable). □ Verify drain pan is properly installed and no leaks on water connection. □ Install anti-tip device(s) and verify unit is secure. □ Install kickplate.
Verify Operations Service & Registration Control Panels If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor in your area.
38 39