Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.
Table of Contents IMPORTANT–Please Read and Follow! Warnings & Important Information________________________________________________________ 3-4 VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36” Dimensions & Specifications _____________________________________________________ 5 Clearance Dimensions ___________________________________________________________ 6 Interior Ventilator Dimensions ____________________________________________________ 7 VWH 18”H.
IMPORTANT–Please Read and Follow! Dimensions & Specifications (VWH 10”H. Wall Hoods w/Standard Ventilator 24”, 30”, & 36”) WARNING To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.) 1. SMOTHER FLAMES with a close fitted lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2.
Clearance Dimensions (VWH 10”H. Wall Hoods w/Standard Ventilator) Interior Ventilator Dimensions (VWH 10”H.
Dimensions & Specifications Clearance Dimensions (VWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”) (VWH 18”H. 27” Deep Wall Hoods 36”, 48”, & 60”) (VWH 18”H. Wall Hoods) NOTE: Optional duct cover sold separately. VWH 18”H. Wall Hoods Description Duct cover width 30” 36” 42” 48” 54” 60” 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 41-7/8” (106.4 cm) 47-7/8” (121.6 cm) 53-7/8” (136.8 cm) 59-7/8” (152.1 cm) 12” (30.5 cm) Duct cover depth 12” (30.
Interior Ventilator Dimensions (VWH 18”H. Wall Hoods) Exterior Ventilator Dimensions (VWH 18”H.
Dimensions & Specifications Clearance Dimensions (VWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”) (VWHO 18”H. Outdoor Wall Hoods) NOTE: Optional duct cover sold separately. VWHO 18”H. Outdoor Wall Hoods Description Duct cover width 36” 48” 60” 35-7/8” (91.1 cm) 47-7/8” (121.6 cm) 59-7/8” (152.1 cm) Duct cover depth 12” (30.5 cm) Duct cover height 12” (30.
Dimensions & Specifications Clearance Dimensions (VCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, 60”, & 66”) (VCWH Chimney Wall Hoods) NOTE: Optional duct cover sold separately. VCWH Chimney Wall Hoods Description 30” 36” 42” 48” 54” 60” 66” Duct cover width 12” (30.5 cm) 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 18” (45.7 cm) 24” (61.0 cm) 24” (61.0 cm) Duct cover depth 12” (30.5 cm) 12” (30.5 cm) to 24” (61.
Interior Ventilator Dimensions (VCWH Chimney Wall Hoods) Exterior Ventilator Dimensions (VCWH Chimney Wall Hoods) Top View Top View 300 or 600 CFM Interior Ventilator Installation for 30”, 36”, & 42” models 900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30”, 36”, & 42” models Top View Top View 1200 CFM Interior Ventilator Installation for 48”, 54”, 60”, & 66” models 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48”, 54”, 60”, & 66” models 16 17
Dimensions & Specifications Clearance Dimensions (DCWH Classic Chimney Hoods 30”, 36”, 42”, & 48”) (DCWH Classic Chimney Hoods) DCWH Classic Chimney Wall Hoods Description Duct cover width 30” 36” 10” (25.4 cm) 12” (30.5 cm) 42” 48” 12” (30.5 cm) 18” (45.7 cm) 12” (30.5 cm) Duct cover depth Duct cover height 18” (45.7 cm) to 30” (76.2 cm) 16” (40.6 cm) to 28” (71.1 cm) 16” (40.6 cm) to 28” (71.1 cm) 16” (40.6 cm) to 28” (71.
Interior Ventilator Dimensions (DCWH Classic Chimney Hoods) Exterior Ventilator Dimensions (DCWH Classic Chimney Hoods) Top View Top View 300 or 600 CFM Interior Ventilator Installation for 30”, 36”, & 42”Hoods 900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30”, 36”, & 42” Hoods Top View Top View 1200 CFM Interior Ventilator Installation for 48” Hoods 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for 48” Hoods 20 21
Dimensions & Specifications Clearance Dimensions (VCIH Chimney Island Hoods 36”, 42”, 54”, & 66”) (VCIH Chimney Island Hoods) NOTE: Optional duct cover sold separately. VCIH Chimney Island Hoods Description Duct cover width 36” 42” 54” 66” 12” (30.5 cm) 12” (30.5 cm) 18” (45.7 cm) 24” (70.0 cm) Duct cover depth 12” (30.5 cm) Duct cover height 12” (30.5 cm) or 24” (61.0 cm) or 36” (91.
Interior Ventilator Dimensions (VCIH Chimney Island Hoods) Exterior Ventilator Dimensions (VCIH Chimney Island Hoods) Top View Top View 600 CFM Interior Ventilator Installation for all Chimney Island Hoods 900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Chimney Island Hoods Top View Top View 1200 CFM Interior Ventilator Installation for all Chimney Island Hoods 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation for all Chimney Island Hoods 24 25
Installing Hood Canopy Dimensions & Specifications (VBCV Wall Custom Ventilator System 30”, 36”, 42”, 48”, 54”, 60” & 66”) Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 25. *For best results, center the unit over the burners of the cooking product (front to back; right to left).
Clearance Dimensions (VBCV Wall Custom Ventilator System) Built-In Wall Custom Ventilator System Dimensions (VBCV Models) For 300, 600 or 1200 CFM Interior Ventilator Installation For 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation 900 or 1200 CFM Exterior or In-Line Ventilator Installation 30”, 36”, 42” W. Models 300 or 600 CFM Interior Ventilator Installation 30”, 36”, 42” W. Models D C 30” W. 36” W. 42” W. 28 30” W. 36” W. 42” W. 28-1/4” (71.8 cm) 34-1/4” (87.
Built-In Wall Custom Ventilator System Dimensions (VBCV Models) 1200 or 1500 CFM Exterior or In-Line Ventilator Installation 48”, 54”, 60”, 66” W. Models Planning Information Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product. • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated.
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) goe here. Check damper for Text unrestricted movement, adjust if necessary. goe Seal here.with aluminum tape. Attach transition to Text damper. CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary.
Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Duct Cover Option Attach with screws and lock washers provided. Attach with screws. (VWH 10”H. Wall Hoods w/Standard Ventilator) WARNING To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Installation (VWH 18”H. Wall & VCWH Chimney Wall Hoods) Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit. Replace electrical box cover. Make connection to breaker box. Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (provided locally) to wall using screws provided. Use additional mounting screws to secure hood to wood strip.
Duct Cover Option (VCWH Chimney Wall Hoods) Slide spacer front over front lip. Push spacer rear up, then slide back over rear lip. Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Measure distance from ceiling to canopy. Tape to avoid scratching. Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place and remove tape.
Installation (VCIH Island Hoods) Check framing where cutout will be. NOTE: 200 lb. limit. Cut appropriate size hole in ceiling. Either 7” or 10” depending on your specific unit and ventillator kit. Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct does not stick down past the cover. Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape. Slide filter front over front lip. Push filter rear up, then slide back over rear lip.
Installation (DCWH Classic Chimney Wall Hoods) Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (not included) to wall using screws provided. Use additional mounting screws to secure hood to wood strip. CAUTION: Secure vent hood to wall using screws provided. Make sure mounting screws are secured into frame. Use additional mounting screws and wall anchors, if necessary.
Service & Registration Wiring Diagram Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician. PROFESSIONAL BUILT-IN HOODS Record the following information indicated below. You will need it if service is ever required.