Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.
Table of Contents IMPORTANT–Please Read and Follow! Warnings & Important Information ______________________________________ 3 Dimensions & Cutout Dimensions ______________________________________ 6 Specifications ________________________________________________________ 7 Custom Door Panel Specifications ______________________________________ 8 Custom Door Panel Installation Option _________________________________ 9 General Information _________________________________________________ 10 Site Preparation
IMPORTANT–Please Read and Follow! WARNING Electrical Shock Hazard Electrically ground dishwasher. Connect ground wire to green ground connector in terminal box. Do not use an extension cord. Failure to follow these instructions, can result in death, fire or electrical shock. IMPORTANT–Please Read and Follow! A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.
Specifications Dimensions & Cutout Dimensions Professional Series 26-3/8” (67.0 cm) 23-1/8” (59.0 cm) 26-3/8” (67.0 cm) 23-3/4” (60.3 cm) 2 3-7/ (60.6 c8” m) Built-In Dishwasher Description 200/325E/450E Models Overall width 2-5/8” (6.7 cm) 3-3/16” (8.1 cm) 33-7/ 8” (86.0 cm) Overall height from floor 23-7/8” (60.6 cm) 33-7/8” (86.0 cm) min. to 35” (89.0 cm) max. Overall depth from rear–Professional To edge of side - 24” (61.0 cm) - includes door panel With door open - 49” (124.
Custom Door Panel (Specifications for FDB200/DFB450E Models) (Installation Option) 11-17/32" (29.3 cm) 5/8" (1.6 cm) 5/8" (1.6 cm) 5/8" (1.6 cm) a Have the overlay panel constructed per dimensions. The panel thickness MAY NOT exceed 5/8” (1.6 cm) for flush installation in most cabinets. Ensure that the design, construction, and installation of the panel overlay and its handle mounting is sufficient to reliably operate in this application with a maximum panel weight of 18 lbs. (8.2 kg.
General Information General Information • Read these instructions carefully and completely before installing the dishwasher. The installation should be carried out by a qualified installer, who is familiar with all local codes and ordinances for electrical and plumbing connections. If the dishwasher is being installed for the first time, most of the work has to be done before you move it into place. If you are replacing an old dishwasher, you must check the old connections.
Hardwire Conduit Option a b Trim Installation Options (not available on all units) To install dishwasher without trim, remove the 6 screws (3 per side) and remove trim. To attach wiper gasket to dishwasher, pull protective film off adhesive back on wiper gaskets and apply to leading edge of dishwasher frame. Trim gasket to fit. 1 1a Remove bottom pan and front plate. Rapid removal of the bottom pan will cause damage to the moisture sensor.
Trim Installation Options (cont’d.) (not available on all units) Dishwasher will ship with trim installed for panel flush install. If needed, attach wiper gasket by pulling protective film off adhesive back on wiper gasket and apply behind hemmed edge of side trim. Trim Installation Options (cont’d.) To install dishwasher cabinet flush with trim, remove the 6 screws (3 per side) holding side trim on. Shift the side trim forward.
Counter Balance Spring Adjustment - If Necessary a b Installation Procedure 1 1b 1 Increase tension 2 Decrease tension 1 Disconnect cable from hook. Set counter balance spring connector in appropriate location. c NOTE: For custom panel installation, the door may require adjustment to the preload of the counterbalance springs. Follow these steps to adjust the tension. Carefully lay dishwasher on its back and attach the kick plate brackets. Screws for the brackets will already be in the base.
Installation Procedure (cont’d.) 5b Installation Procedure (cont’d.) Front Panel Attached 7 7b Front Panel Removed Attach screws through trim pieces into cabinets. (select models). Attach screws through bracket into cabinets (select models). Remove front panel to access the front leveling legs. 9 8 5c 1.0” (2.5 cm) 6 Minimum 20” (50.8 cm) from floor Cut here for 5/8” (1.6 cm) Cut here for 3/4” (1.9 cm) Leveling legs will be raised during shipping.
Installation Procedure (cont’d.) 11A Air Gap 11B Air Gap Performance Checklist Testing for Leaks Unit Reset A qualified installer should carry out the following checks: • If the unit should need to be reset for any reason, push and hold the “START” button for 4 seconds. h Remove packaging and parts. h Turn on the water supply and check for leaks.
Service & Registration Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All servicing should be referred to a qualified technician.