Quick Start Guide

6
Clearance Dimensions (proximity to cabinets)
•This range may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.
IMPORTANT: The side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. This can be accomplished by
raising the unit using the adjustment spindles on the legs.
The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above
36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the range to such combustible surfaces above
the 36” (91.4 cm) counter height.
Within the 8” (20.3 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth
must be 13” (33.0 cm) and wall cabinets within this 8” (20.3 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high
countertop.
Wall cabinets above the range must be a minimum of 46” (116.8 cm) above the range cooking surface for the full width of the
range. This minimum height requirement does not apply if a range hood is installed over the cooking surface.
46” min.
(116.8 cm)
13” max.
(
33.0 cm)
8” min.
(20.3 cm)
18” min.
(45.7 cm)
3/8”
(0.95 cm)
36”
(
91.4 cm)
A
(opening width)
BURN HAZARD
To avoid risk of personal
injury; the use of cabinets for
storage above the appliance
may result in a potential
burn hazard. Combustible items may
ignite, metallic items may become hot
and cause burns. If a cabinet storage is
to be provided the risk can be reduced
by installing a rangehood that projects
horizontally a minimum 5” (12.7 cm)
beyond the bottom of cabinets.
CAUTION
Note: Minimum clearance for back wall is 3/4” (1.9 cm)
with backguard or high-shelf to allow for rear stando s
against a combustible wall. There must be a minimum of
6” (15.2 cm) clearance from rear of range to a combustible
wall with an island trim.
Note: If a range hood is installed, wall cabinets above the
range have a di erent minimum clearance height.
Range
Width
“A”
Dimension
30” 30” (76.2 cm)
36” 36” (91.4 cm)
Important: Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certi ed
by CSA. Clearances to non-combustible materials must be
approved by the authority having jurisdiction.