LP/Propane Conversion Kit - LPKVGR - Installation Instructions

4 5
Regulator Conversion
LP
Orientation
NAT
LP
Natural
Orientation
NAT
LP
Apply sideways finger pressure
to remove pin from cap.
NAT
LP
conversion
conversion
•Remove hex nut from top of regulator.
•Unsnap plastic plunger from hex nut.
Reverse plunger and reinstall onto hex nut by
pressing fi rmly.
NOTE: Plunger is marked “NAT” or “LP”.
Converted fuel type will be shown on the lower
portion of plunger.
Reinstall hex nut onto regulator in confi guration
desired.
Infrared Broiler Conversion
IMPORTANT: The infrared broiler orifi ce must
be changed from rear of range before unit is
installed. The island trim and rear panel must be
removed to access infrared broiler.
-Locate bag labeled 050280-000
- Remove nut securing 90 degree fi tting and
broiler tubing to rear of range.
- Remove orifi ce from 90º fi tting and replace with
orifi ce #56 from the bag labeled 050280-000.
Reverse procedure to reassemble.
Broil Nut
NOTE: VGR748 models have two regulators. Make sure both regulators
are converted. To access second regulator, the island trim and small panel
on the back must be removed
Second regulator located behind small
panel on VGR748 Gas Ranges.
Remove rear panel to access infrared broiler orifi ce.