Installation Instructions

4
Basic Specifications
Dimensions
5
DDeessccrriippttiioonn
VVGGWWTTOO55224411
Overall Width 24 3/4” (62.9 cm)
Overall Depth from Rear To end of side panel - 28 5/8” (72.7 cm)
T
o endo of control panel - 31” (78.7 cm)
To end of knobs - 32 3/4” (83.2 cm)
Overall Height To cooking surface 11 3/4 (29.8 cm)
Cutout Width 26 1/4 (66.7 cm)
Cutout Depth Minimum - 27 3/8” (69.5 cm)
Maximum - 27 7/8” (70.8 cm)
Cutout Height 10-1/4 (26.0 cm)
Gas Requirements Natural: standard residential 1/2 (1.3 cm) ID gas service line.
LP/Propane: standard residential 1/2 (1.3 cm) ID gas service line. or
equipped with high capacity hose/regulator assembly for connection
to standard 20 lb. LP/Propane gas cylinder with Type 1, QCC-1
connection.
UUnniitt mmuusstt bbee oorrddeerreedd NNaattuurraall oorr LLPP//PPrrooppaannee -- NNoott FFiieelldd CCoonnvveerrttiibbllee
12 V - (8 AA batteries)
Electrical Requirements
Burner Rating 27,500 BTU Nat./27,500 BTU LP
(8.1 kW Nat./8.1 kW LP)
Approximate Shipping Wt. 160 lbs. (72.0 kg)
26-1/4”
(66.7 c
m)
28-5/8”
(72.7
cm
)
32-3/4”
(83.2 cm
)
Built-in Installation
1. A minimum of 6” (15.2 cm) from the sides must be maintained from the unit above the cooking surface to adjacent vertical
combustible construction. The unit is not to be located under overhead unprotected combustible construction.
2. The side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop
3
. When determining a suitable location for the unit, take into account concerns such as exposure to wind, proximity to traffic
p
aths and keeping gas supply lines as short as possible. Locate only in a well-ventilated area. Never locate in a building,
g
arage, breezeway, shed or other such enclosed areas.
4. In a built-in construction where an LP/Propane tank is going to be used, there MUST be some type of support (braces, cut-
out, etc.) to prevent tank from moving within the installation. The support must also allow the LP/Propane tank to withstand
a horizontal tipping force equal to the weight of the tank without tipping over. The tank can not tip over or deflect more
than 1.00 inch when a 38 lb. horizontal force is applied to a 20 lb. LP/Propane tank.
IIMMPPOORRTTAANNTT:: GGaass ffiittttiinnggss,, rreegguullaattoorr,, aanndd iinnssttaalllleerr ssuupppplliieedd sshhuutt--ooffff vvaallvvee mmuusstt bbee eeaassiillyy aacccceessssiibbllee..
1
0
-
1
/
4
(
2
6
.
0
c
m
)
3
6
(
9
1
.
4
cm
)
2
7
-
3
/
8
(
6
9
.
5
cm
)
2
4
-
3
/
4
(
6
2
.
9
c
m
)
*
S
o
l
i
d
b
o
t
t
o
m
s
u
p
p
o
r
t
Countertop typically
requires 1/2” wide by 1/2”
deep notch cutout on each
side of grill. This allows grill
Control Panel to sit back
properly in the cutout.
6”
m
i
n
(
1
5
.
2
c
m
)
Gas inlet
location area
5
(
1
2
.
7
c
m)
5
(
1
2
.
7
c
m)
1
/
2
(
1
.
2
c
m
)
1
/
2
(
1
.
2
c
m
)