Installation Instructions
76
1. At least one ventilation opening shall be provided on the
exposed exterior side of the enclosure located within 5
inches (127 mm) of the top of the enclosure and
unobstructed. The opening(s) shall have a total free area
of not less than 1 in
2
/lb (14.2 cm
2
/kg) of stored fuel
capacity.
2. At least one ventilation opening shall be provided on
the exposed, exterior side of the enclosure 1 inch (25.4
mm) or less from the floor level and shall have a total
free area of not less than 1/2 in
2
/lb (7.1 cm
2
/kg) of
stored fuel capacity. The upper edge shall be no more
than 5 inches (127 mm) above the floor level.
3. Every opening shall have a minimum dimension so as to
permit the entrance of a 1/8 inch (3.2 mm) rod.
Ventilation for Built-in Installation
Vents
1.00 inch maximum
5.00 inch
maximum
All vents no more than 5.00 inches
above the floor of the installation.
5.00 inch
maximum
Not more than 5.00
inches from inside
bottom of countertop.
Bottom Vent not
more than 1.00 inch
from inside floor of
installation.
Vents located
on sidewall
Male Male
couplercoupler
Installer supplied
flexible gas line
with 1/2” female
adapter or GHS12
Installer supplied
shut-off valve must
be easily accessible
7/8” male
flare adapter
Regulator
Assembly
3/8” 3/8”
male male
flare flare
dapterdapter
1/2”
NPT
from
Manifold
Natural Fixed Piping Connection
Connection: Standard Residential 1/2” ID gas service line - 1/2” NPT male with 7/8” flare adapter.
Operating Pressure: 4.0” W.C.P. Nat.
Supply Pressure: 6” to 10” W.C.P. Nat. If in excess of 10” W.C.P., a step-down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on
type and size of run and how deep to bury the lines. If the gas line is too small, the unit will not function properly.
To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 7/8” (2.2 cm) female flare adaptor
to the 7/8” (2.2 cm) male flare adaptor on the regulator assembly. Ensure that the regulator arrow points in the direction of the
gas flow towards the unit and away from the supply. Connect the regulator assembly to the grill unit . All connectors need to
comply with ANSI Z21.75/ CSA 6.27. When using semi-ridged tubing, aluminum or aluminum alloy tubing is not permitted.
DDOO NNOOTT ffoorrggeett ttoo ppllaaccee tthhee iinnssttaalllleerr ssuupppplliieedd ggaass vvaallvvee iinn aann aacccceessssiibbllee llooccaattiioonn..
NNOOTTEE:: IIff uussiinngg aa GGSSHH1122 fflleexxiibbllee hhoossee,, rreemmoovvee tthhee 11//22”” ffllaarree aaddaapptteerr aanndd aattttaacchh hhoossee ttoo tthhee tthhee 11//22”” ((11..33 ccmm)) mmaallee ffllaarree oon