User Manual

INSTALLATION / USE & CARE
|
9
5”
4.5”
3”
AA
B
C
COUNTER TOP NOTCH DETAIL
Only required if island counter top overhangs the face of the island
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
3/4” Pipe (in feet)
Max BTU for all
Appliances on line
10 360,000
20 245,000
30 198,000
40 169,000
50 150,000
60 135,000
70 123,000
80 115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL-SPECIFIC BTU OUTPUTS
MODEL H BURNER (Btu) ROTISSERIE (Btu) PROSEAR™ (Btu) TOTAL INPUT
VQGI5301/VQGFS5301 (N/L)SS 1 @ 25,000 1 @ 14,000 1 @ 21,000 62,000 Btu/Hr
VQGI5361/ VQGFS5361 (N/L)SS 2 @ 25,000 1 @ 14,000 1 @ 21,000 87,000 Btu/Hr
VQGI5421/ VQGFS5421 (N/L)SS 2 @ 25,000 1 @ 16,000 1 @ 21,000 89,000 Btu/Hr
VQGI5541/ VQGFS5541 (N/L)SS 3 @ 25,000 2 @ 14,000 1 @ 21,000 126,000 Btu/
Hr