LEAK TESTING
Leak Test Procedure:
• Create a soapy solution of 1 part soap and 3 parts water.
• Con rm that all control knobs are in the o position.
• Turn on the fuel supply. For natural gas, turn the valve handle
1/4 turn to align with the gas ow.
• For L.P., turn the cylinder valve knob counter clockwise one
full rotation.
• Apply the soap solution generously by paint brush or squirt
bottle on all connections and ttings.
• If bubbles appear to “grow” on any of the connections, you
have a gas leak. IMMEDIATELY turn o the gas supply.
Fixing a Gas Leak:
• Shut o the gas supply
• Turn all grill controls to the “ON” position to purge the grill of
any gas build-up, then turn the controls back “OFF”.
• Wash o the soapy solution with cold water and dry.
• Tighten the loose joint, or replace the faulty part with manu-
facturer-recommended replacement parts.
• DO NOT attempt to repair the L.P. cylinder valve if it is dam-
aged. The only way to safely resolve a damaged cylinder is to
REPLACE IT.
• Repeat the leak test to ensure that no leaks are present.
LOW HEAT BURNER ADJUSTMENT
FOR MAIN BRASS BURNERS AND SIDE BURNERS ONLY!
DO NOT ADJUST THE ROTISSERIE BURNER.
The main brass burners and side burners on your grill feature an
adjustable low setting.
Fluctuations in gas pressure, gas conversion and even in the
quality of the gas itself may a ect burner performance at the
“LOW” setting. It could be either too high or too low.
To Adjust the Burner to a Low Setting:
• Make sure the grill is cool.
• Remove the racks so you can see the ames while adjusting
the burners.
• Light the burner and allow it to preheat on high for 3 minutes.
• Turn the burner to “LOW”.
• Pull o the control knob.
• While holding the valve shaft with pliers as shown insert a
small at screwdriver into the center shaft and adjust the
ame’s low setting.
Clockwise will lower the ame setting, counterclockwise will
raise it.
The proper setting is where the ame is stable at its lowest set-
ting. A slight utter will be present in the crossover portion of the
front of the burner before the burner itself becomes weak.
The factory setting for propane gas is ½ to ¾ turn from the very
bottom of the adjustment. The setting for natural gas is 1-½ to
1-¾ from the bottom. After the low settings are proper, turn all
burners to high for visual inspection.
Please note the low ame adjustment is not available for the
rotisserie valve.
To prevent re or explosion hazard, DO NOT smoke or
allow any potential source of ignition (sparks, electri-
cal arcing, etc) in the area while performing a leak
test. Leak tests should be conducted outdoors only.
Never conduct a leak test using re or ame.
DANGER!