1. Run 10" round steel ductwork, from exterior ventilator to
the installation location. For best performance, use the
straightest possible duct run and the fewest number of
elbows. Tape all joints.
2. Run 120 VAC electrical power cable from service panel
and from remote ventilator to installation location.
3. Remove wiring box cover. Remove knockouts from the
wiring box. Feed 6" of power cable through openings
and attach cables to wiring box with appropriate connec-
tors.
VIKING RANGE00'
GREENWOOD, MISSISSIPPI 38930 USA
4. Wire black to black, white to white, and green or bare
wire beneath green ground screw. Replace wiring box
cover.
5. Connect ductwork to transition and tape joint.
6. Turn on power and check ventilator operation.
INSTALL THE ROUGH-IN PLATE USE AND CARE
Disconnect electrical power supply and lock out service
panel before cleaning or servicing this unit.
CLEANING
Remove cover and carefully vacuum ventilator and inside
of housing. Be careful not to bend or otherwise damage
ventilator wheel.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disas-
semble motor.