Installation Professional Indoor & Outdoor Hoods VWH53012 / CVWH53012 / VWH53612 / CVWH53612 VWH53048 / CVWH53048 / VWH53648 / CVWH53648 / VWH54248 / CVWH54248 / VWH54848 / CVWH54848 / VWH56048 / CVWH56048 VCWH53048 / CVCWH53048 / VCWH53648 / CVCWH53648 / VCWH54248 / CVCWH54248 / VCWH54848 / CVCWH54848 / VCWH56048 / CVCWH56048 VCIH53608 / CVCIH53608 / VCIH54208 / CVCIH54208 / VCIH55408 / CVCIH55408 / VCIH56608 / CVCIH56608 VBCV53638 / CVBCV53638 / VBCV54238 / CVBCV54238 / VBCV54838 / CVBCV54838 / VBCV56038
Table of Contents Warnings & Important Information________________________________________________________ 3-4 VWH/CVWH 10” H/12”H. Wall Hoods w/Standard Ventilator 30”, & 36” Dimensions & Specifications _____________________________________________________ 5 Clearance Dimensions ___________________________________________________________ 6 Interior Ventilator Dimensions ____________________________________________________ 7 VWH/CVWH 18”H.
IMPORTANT–Please Read and Follow! NOTE: If installing hood with warming shelf panel, install warming shelf panel first. WARNING To reduce the risk of fire, electric shock, or injury to persons, observe the following: IMPORTANT – PLEASE READ AND FOLLOW • Before beginning, please read these instructions completely and carefully. • Do not remove permanently affixed labels, warnings, or plates from the product. This may void the warranty. • Please observe all local and national codes and ordinances.
IMPORTANT–Please Read and Follow! WARNING WARNING To reduce the risk of injury to persons in the event of a rangetop grease fire, observe the following. (Based on “Kitchen Firesafety Tips,” published by NFPA.) This appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
Dimensions & Specifications (VWH 10”H./12”H. Wall Hoods w/Standard Ventilator 30”, & 36”) 1 (30 2 ” .5 cm ) (2510” .4 c (12 5” .7 cm m) ) ” 21 cm) A .3 (53 1 30”W. 36”W. (30 2 ” .5 cm ) A (Hood width) 29-7/8“ (76.2 cm) 35-7/8” (91.1 cm) 1 (30 2 ” .5 cm ) (12 5” .7 cm ) ” 21 cm) A .3 (53 30”W. 36”W. A (Hood width) 29-7/8“ (76.2 cm) 35-7/8” (91.1 cm) NOTE: Optional duct cover sold separately. VWH/CVWH 10”H./12”H.
Clearance Dimensions (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) 60 24 (15" m 2.4 in. c 63 to m) " (16 m 0.0 ax. cm ) (61" mi .0 n. c 27 to m) "m (68 a .6 x.* cm ) " 36 cm) .4 (91 * NOTE: When installing with a 24” high-shelf, the 27” (68.6 cm) max. dimensions must be used.
Interior Ventilator Dimensions (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) Top View 24”W. 30”W. 36”W. A 23-7/8” (60.6 cm) 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 24”W. 30”W. 36”W. B 5-1/4” (13.3 cm) 8-1/4” (20.9 cm) 11-1/4” (28.6 cm) 24”W. 30”W. 36”W. C 11-15/16” (30.3 cm) 14-15/16” (37.9 cm) 17-15/16” (45.6 cm) 24”W. 30”W. 36”W. D 5/8” (1.6 cm) 3-5/8” (9.2 cm) 6-5/8” (16.8 cm) A 18” (4.6 cm) B D 3-4” (1.9 cm) C 4” (10.2 cm) 3-7/8” (9.8 cm) 7” (17.8 cm) dia.
Dimensions & Specifications (VWH/CVWH 18”H. 24” Deep Wall Hoods 30”, 36”, 42”, 48”, & 60”) 30" W 36" W 42" W 48" W 60" W A 29-7/8" (76.2 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 59-7/8" (152.1 cm) (3012" .5 cm ) (15 6" .2 cm (4518" .7 cm ) ) A " 24 cm) .0 (61 NOTE: Optional duct cover sold separately. VWH/CVWH 18”H. Wall Hoods Description Duct cover width 30” 36” 42” 48” 60” 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 41-7/8” (106.4 cm) 47-7/8” (121.6 cm) 59-7/8” (152.
Clearance Dimensions (VWH/CVWH 18”H. Wall Hoods) 66 (16” m 7.6 in. c 72 to m) ” (18 m 2.9 ax. cm ) 30 (76” mi .2 n. c 36 to m) ” (91 ma .4 x. cm ) ” 36 cm) .
Interior Ventilator Dimensions (VWH/CVWH 18”H. Wall Hoods) Top View A 30" W 36" W 42" W 48" W 60" W A 14-15/16" (37.9 cm) 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) 23-15/16" (60.8 cm) 29-15/16" (76.0 cm) 30" W 36" W 42" W 48" W 60" W 4-5/8" (11.7 cm) B 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 59-7/8" (152.1 cm) 7" (17.8 cm) dia.
Exterior Ventilator Dimensions (VWH/CVWH 18”H. Wall Hoods) Top View A 30" W 36" W 42" W 48" W 60" W A 14-15/16" (37.9 cm) 17-15/16" (45.6 cm) 20-15/16" (53.2 cm) 23-15/16" (60.8 cm) 29-15/16" (76.0 cm) 30" W 36" W 42" W 48" W 60" W 5-15/16" (15.1 cm) B 29-7/8" (75.9 cm) 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 47-7/8" (121.6 cm) 59-7/8" (152.1 cm) 10" (25.4 cm) dia.
Dimensions & Specifications (VWHO/CVWHO 18”H. Outdoor Wall Hoods 36”, 48”, & 60”) Seal joints with silicone. Provided on “T” Series only. (3012" .5 cm ) (15 6" .2 cm (4518" .7 cm ) ) A 35-7/8" (91.1 cm) 47-7/8" (121.6 cm) 59-7/8" (152.1 cm) 36" W 48" W 60" W " 27 cm) A .6 (68 NOTE: Optional duct cover sold separately. VWHO/CVWHO 18”H. Outdoor Wall Hoods Description Duct cover width 36” 48” 60” 35-7/8” (91.1 cm) 47-7/8” (121.6 cm) 59-7/8” (152.1 cm) 12” (30.
Clearance Dimensions (VWHO/CVWHO 18”H. Outdoor Wall Hoods) " 18 ) m c 5.7 » «X M 1/2") I D 4- m + 1.4 c (4 (1 " 27 cm) .6 (68 66 (16" m 7.6 in. c 72 to m) (18" m 2.9 ax. cm ) 30 (76" m . 2 in. c 36 to m) "m (91 a .4 x. cm ) " 36 cm) .4 (91 Note: Outdoor Models must be installed in a covered, non-enclosed area, and should be protected from the elements as much as possible. The bottom of the hood should be 30” (76.2 cm) to 36” (91.4 cm) above the grill surface.
Dimensions & Specifications (VCWH/CVCWH Chimney Wall Hoods 30”, 36”, 42”, 48”, 54”, & 60”) A 30”W. 36”W. 42”W. 48“W. 60”W. 66”W. A (Duct width) 12“ (30.5 cm) 12“ (30.5 cm) 12“ (30.5 cm) 18“ (45.7 cm) 24“ (61.0 cm) 24“ (61.0 cm) B (Hood width) 30”W. 29-7/8“ (76.2 cm) 36”W. 35-7/8” (91.1 cm) 42”W. 41-7/8” (106.4 cm) 48“W. 47-7/8” (121.6 cm) 60”W. 59-7/8” (152.1 cm) 66”W. 65-7/8” (167.3 cm) (3012” .5 c to m) (6124” .0 cm ) (15 6” .2 cm ) (4518” .7 cm ) ” 24 cm) B .
Clearance Dimensions (VCWH/CVCWH Chimney Wall Hoods) 66 (16” m 7.6 in. c 72 to m) (18” m 2.9 ax. cm ) 30 (76” mi .2 n. c 36 to m) ”m (91 a .4 x. cm ) ” 36 cm) .
Interior Ventilator Dimensions (VCWH/CVCWH Chimney Wall Hoods) Top View 12” (30.5 cm) 120V power supply 1-1/2” (3.8 cm) A 30”W. 36”W. 42”W. A 14-15/16” (37.9 cm) 17-15/16” (45.6 cm) 20-15/16” (53.2 cm) 30”W. 36”W. 42”W. B 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 41-7/8” (106.4 cm) 6” (15.2 cm) 1-1/2” (3.8 cm) 7” (17.8 cm) dia. duct location B 300 or 600 CFM Interior Ventilator Installation for 30”, 36”, & 42” models Top View C 1-1/2” (3.8 cm) 120 V power supply A 48”W. 60”W. 66”W.
Exterior Ventilator Dimensions (VCWH/CVCWH Chimney Wall Hoods) Top View 12” (30.5 cm) 1-1/2” (3.8 cm) 120V power supply A 30”W. 36”W. 42”W. A 14-15/16” (37.9 cm) 17-15/16” (45.6 cm) 20-15/16” (53.2 cm) 30”W. 36”W. 42”W. B 29-7/8” (75.9 cm) 35-7/8” (91.1 cm) 41-7/8” (106.4 cm) 6” (15.2 cm) 1-1/2” (3.8 cm) 10” (25.4 cm) dia. duct location B 900 or 1200 CFM Exterior or In-Line Ventilator Installation for 30”, 36”, & 42” models Top View C 1-1/2” (3.8 cm) 120 V power supply A 48”W. 60”W. 66”W.
Dimensions & Specifications (VCIH/CVCIH Chimney Island Hoods 36”, 42”, 54”, & 66”) A A 12" (30.5 cm) 12" (30.5 cm) 18" (45.7 cm) 24" (70.0 cm) 36" W 42" W 54" W 66" W B 12" (30.5 cm) or 24" (61.0 cm) or 36" (91.4 cm) 36" W. 42" W. 54" W. 66" W. 36" W 42" W 54" W 66" W (15 6" .2 cm B ) (4518" .7 cm ) C 35-7/8" (91.1 cm) 41-7/8" (106.4 cm) 53-7/8" (136.8 cm) 65-7/8" (167.3 cm) " 30 cm) C .2 (76 NOTE: Optional duct cover sold separately.
Clearance Dimensions (VCIH /CVCIHChimney Island Hoods) 66 (16” m 7.6 in. c 72 to m) ” (18 m 2.9 ax. cm ) 30 (76” min .2 c . m 36 to ) ” (91 max .4 c . m) ” 36 cm) .
Interior Ventilator Dimensions (VCIH/CVCIH Chimney Island Hoods) Top View 12” (30.5 cm) 36”W. 42”W. A 17-15/16” (45.6 cm) 20-15/16” (53.2 cm) 36”W. 42”W. B 35-7/8” (91.1 cm) 41-7/8” (106.4 cm) 1-1/8” (2.9 cm) 120 V power supply A 1-1/8” (2.9 cm) 6” (15.2 cm) 7” (17.8 cm) dia. duct location B 600 CFM Interior Ventilator Installation for all Chimney Island Hoods Top View C 54”W. 66”W. A 26-15/16” (68.4 cm) 32-15/16” (83.7 cm) 54”W. 66”W. B 53-7/8” (136.8 cm) 65-7/8” (167.3 cm) 54”W. 66”W.
Exterior Ventilator Dimensions (VCIH/CVCIH Chimney Island Hoods) Top View 12” (30.5 cm) 36”W. 42”W. A 17-15/16” (45.6 cm) 20-15/16” (53.2 cm) 36”W. 42”W. B 35-7/8” (91.1 cm) 41-7/8” (106.4 cm) 1-1/8” (2.9 cm) 120 V power supply A 1-1/8” (2.9 cm) 6” (15.2 cm) 10” (25.4 cm) dia. duct location B 900 or 1200 CFM Exterior or In-Line Ventilator Installation for all Chimney Island Hoods Top View C 54”W. 66”W. A 26-15/16” (68.4 cm) 32-15/16” (83.7 cm) 54”W. 66”W. B 53-7/8” (136.8 cm) 65-7/8” (167.
Dimensions & Specifications (VBCV Wall Custom Ventilator System 36”, 42”, 48”, & 60”) A* *For best results, center the unit over the burners of the cooking product (front to back; right to left). Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 25. B* Bottom Cutout Dimensions Wall Hoods Description 36” 42” 48” 60” W. W. W. W. A (Hood Width) B (Hood Depth) 33-7/16” (84.9 cm) 39-7/16” (100.2 cm) 45-7/16” (115.
Installing Hood Canopy (Custom Hood Canopy Cutouts) Custom Hood Canopy A B 1) Position ventilator system inside of the custom hood canopy and center it front to back and left to right. Built-In Ventilator System 2) Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided. 3) OPTIONAL Rear mounting holes fasten ventilator system to rear of custom hood canopy.
Clearance Dimensions (VBCV/CVBCV Wall Custom Ventilator System) (Cu sto m Ho od ) 66 (16" m 7.6 in. c 72 to m) " (18 m 2.9 ax. cm ) 30 (76" mi .2 n. c 36 to m) "m (91 a .4 x. cm ) " 36 cm) .
Built-In Wall Custom Ventilator System Dimensions (VBCV Models) 1-1/2” (3.8 cm) 1" (2.54 cm) 1-1/2" (3.81 cm) 7/8” (2.2 cm) 11-1/2” (29.2 cm) 17-1/4” (43.8 cm) 6” (15.2 cm) 5/8" (1.6 cm) 5/8” (1.6 cm) 21-7/8” (55.8 cm) 21-7/8po (55.8 cm) For 300, 600 or 1200 CFM Interior Ventilator Installation For 900, 1200 or 1500 CFM Exterior or In-Line Ventilator Installation D D 4-5/8" (11.7 cm) 5-1/2" (14.0 cm) 7" (17.8 cm) dia. duct location 10" (25.4 cm) dia. duct location 5/8" (1.6 cm) 5/8" (1.
Built-In Wall Custom Ventilator System Dimensions (VBCV/CVBCV Models) D 5-1/2" (14.0 cm) 10" (25.4 cm) dia. duct location 5/8" (1.6 cm) C 1200 or 1500 CFM Exterior or In-Line Ventilator Installation 48”, 60” W. Models D 5-1/2" (14.0 cm) 10" (25.4 cm) dia. duct location 5/8" (1.6 cm) C 1200 CFM Interior Ventilator Installation 36”, 42”, 48”, 60” W. Models C 36” 42” 48” 60” W. W. W. W. D 34-1/4” (87.0 cm) 40-1/4” (102.2 cm) 46-1/4” (117.5 cm) 58-1/4” (148.0 cm) 36” 42” 48” 60” 26 W. W. W. W.
Planning Information Proper installation of ducting is extremely important to ensure maximum performance from any ventilation product. • All CFMs are based on tests at 0.1 static pressure: without applying static pressure, CFM would be greatly overstated. • Straight runs and gradual turns are best; for example, each 90º elbow is equivalent to 5-10 feet (1.52-3.05 cm) of straight run. • Never use flexible duct; it creates back pressure/air turbulence and greatly reduces performance.
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) 2 1 Check damper for unrestricted movement, adjust if necessary. Attach transition to damper. Seal with aluminum tape. WARNING 3 To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
6 Nut driver 5/16” 5/16” Nut driver CAUTION: If not using a duct cover, using screws provided, make sure top mounting screws are secured into soffit or cabinet framing. Use additional mounting screws, if necessary. CAUTION: Secure vent hood to wall using screws provided. Use additional mounting screws and wall anchors, if necessary. 7 8 Bare or Green 1 1 2 Green Black White Black White Connect black to black, white to white, and the green/bare wire under the green screw.
Duct Cover Option (VWH/CVWH 10”H./12”H. Wall Hoods w/Standard Ventilator) 1 2 Measure distance from ceiling to canopy. 2 Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit) 1 2 Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood upside down on recirculating unit.
Installation (VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit) 3 4 Attach with screws and lock washers provided. Attach with screws. WARNING 5 To reduce the risk of fire, electric shock, or injury to persons, observe the following: • Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. • Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.
Installation (con’t) (VWH/CVWH 10”H./12”H. Wall Hoods w/Recirculating Kit) 8 9 Bare or Green 1 1 2 Green Black White Black White Connect black to black, white to white, and the green/bare wire under the green screw. NOTE: Housing wiring must be properly installed for wiring to be correct when wiring unit. Replace electrical box cover. Make connection to breaker box. 10 11 1 2 3 Slide filter front over front lip. Push filter rear up, then slide back over rear lip.
Installation (VWH/CVWH 18”H. Wall & VCWH Chimney Wall Hoods) *For VCWH hoods, begin with Step 3. The VCWH hoods do not require the wood strip 1 1-1/2” x 3/4” (3.8 cm) x ( 1.9 cm) 1(4.13/1 6 c 6” m) 2 5/16” Nut driver 5/16” Nut driver wood strip VWH/CVWH only! Measure down 1-13/16 (4.6 cm) from desired height of hood and secure 1-1/2” x 3/4” wood strip (provided locally) to wall using screws provided. VWH/CVWH only! Use additional mounting screws to secure hood to wood strip.
Duct Cover Option (VWH/CVWH 18”H. Wall Hoods) 2 1 Measure distance from ceiling to canopy. 2 Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided. To install ventillation kit refer to ventillation kit installation instructions.
Duct Cover Option (VCWH/CVCWH Chimney Wall Hoods) 1 2 Measure distance from ceiling to canopy. Tape to avoid scratching. 3 4 2 Place duct cover top inside duct cover base and lower until desired height is found. Mark height. Use the retaining nuts and bolts to fasten in place and remove tape. Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided.
Installation (VCIH/CVCIH Island Hoods) 2 1 Check framing where cutout will be. NOTE: 200 lb. limit. Cut appropriate size hole in ceiling. Either 7” or 10” depending on your specific unit and ventillator kit. A1 Mounting options: Using duct cover with ceiling mounting bracket. (Option A - VCIH only) Using threaded rod for additional support. (Option B) Attaching hood directly to soffit or duct cover. (Skip to step 3) Attach duct cover to optional ceiling mounting bracket.
Installation (VCIH/CVCIH Island Hoods) 4 3 5/16” Nut Driver Run duct work down to bottom edge of duct cover/soffit and secure in place. Make sure the duct does not stick down past the cover. Attach canopy to duct cover/soffit. Seal top of hood to duct with aluminum tape. 6 5 1 1 1 3 3 2 2 Slide filter front over front lip. Push filter rear up, then slide back over rear lip. Slide filter front over front lip. Push filter rear up, then slide back over rear lip.
Service & Registration If service is required, call your dealer or authorized service agency. The name of the authorized service agency can be obtained from the dealer or distributor in your area. Have the following information readily available. • Model number • Serial number • Date purchased • Name of dealer from whom purchased Clearly describe the problem that you are having.
Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit our web site at vikingrange.com in the US brigade.