PGM Options
In case the I/Os are programmed as outputs, their
output functions can be programmed to follow module
status, or other events. These are set by the PGM
Options.
For both ports, the activating condition (module status
or event) can be programmed separately. This can be
combined with a second condition according to a
decision logic. Also, the operating mode of the output
(monostable, bistable or follow) and the timing of the
monostable mode can be set.
More info: see, 4.3 PGM Examples
4. Operation
The operation and status of the VBIP Module is
displayed on the status and network LEDs as follows:
4.1. Status LED Display
4.1.1. LED1
Program mode
Programming in progress
Ready, no external line
Ready, external line present
(w/ VBIP-XT card only)
Communication in progress
Low Power Supply
4.1.2. LED2
This LED supports auxiliary information, e.g. signals the
reception during communication.
4.2.
Network LED Display
The activity of the ethernet interface of the module is
indicated by the LED3 and LED4, as follows:
LED3 LED4 Description
off off
No connection, the cable is not
plugged in.
slow
flash
off
IP address inquiry in progress
(DHCP)
fast
flash
off
Cannot resolve server IP
(DNS error, unknown server name)
on TX/RX
Network is configured properly
LED4 shows network traffic
slow
flash
flash
Problem on the local network
(LAN)
fast
flash
flash
Problem with internet connection
(WAN)
on flash
Monitoring server is not found on
the network
4.3. PGM Examples
The programming of the PGM outputs can be very
flexible. The following examples show solutions for
common situations.
4.3.1 Power failure indication
(continuous)
Condition inv A-B relation
Mode Time Code
A. PowerFail n - follow - - - - - -
4.3.2 3 Seconds impulse at line fault
(w/ VBIP-XT card)
Condition inv A-B relation
Mode Time Code
A. LineFail n - trigger 003 - - -
4.3.3 Follow port B status (negated)
Condition inv A-B relation
Mode Time Code
A. Input y - follow - - - - - -
4.3.4 5 seconds impluse at given code (e.g. 1130)
Condition inv A-B relation
Mode Time Code
A. Code n - trigger 005 1130
4.3.5 Input B will toggle Port A at Comm Fault
Condition inv A-B relation
Mode Time Code
A. Input n A and B toggle - - - - - -
B. CommFail n - - - - - - - - - - - -
4.3.6 Any of two events activate Port A for 30 sec.
feltétel inv A-B reláció üzemmód Idő kód
A. Code n A or B trigger 030 1401
B. Code n - - - - - - - - - 3401
5. Specifications
Technical specifications of the VBIP Modules
Power Supply
10.5 – 15.0 VDC
Max. Power Consumption
160 mA
Operating Temperature
0 – 50 °C
Ethernet Connection
10 Base-T
Size
48 mm x 42 mm x 15 mm
Weight
approx. 40 g
The VBIP Module conforms with the following EU
Standards: LVD 73/23/EEC (93/68/EEC), EMC
89/336/EEC (92/31/EEC, 93/68/EEC).
Security Classification according to EN50131-1:
Class II, Grade 3
VILLBAU Security Systems Ltd.
1182 Budapest, Üllői út 611., HUNGARY
Tel: (+36 1) 2975125, Fax: (+36 1) 2942928
www.villbau.com, e-mail: mail@villbau.com