ENIGMA II Monitoring Receiver Programming Manual 6 / 11 / 2014
CONTENT 1. INTRODUCTION.......................................................................................................................3 2. SYSTEM STRUCTURE.............................................................................................................4 2.1 CPM card..............................................................................................................................4 2.2 LC telephone line card (optional).............................................................
1. INTRODUCTION Thank you for choosing our product. This modern and reliable monitoring receiver not only guarantees the highest level of security, but also it is a useful colleague in the life of every monitoring company, because of its user-friendly handling and intelligent functions. To use the highest range of provided functions please read carefully the Programming Manual.
2. SYSTEM STRUCTURE ENIGMA II monitoring receiver provides complex and reliable solution to build up a modern monitoring station. The device can receive signals from alarm control panels through IP network, telephone line and radio channel. Due to the universal operation, the device can receive all standard (and most of the non-standard) signals from alarm control panels and communicators.
2.3 RC radio receiver card (optional) The optional RC radio receiver card works as a special line card in the system – it provides event receiving through UHF radio (440..450MHz). RC card can handle two independent radio channels, which are displayed as line card “A” and “B” in the system. Event management and CPM monitoring way is similar to LC line cards. In standalone mode the RC card can store up to 500 events, which will be sent automatically to CPM when the connection is restored. 2.
SURGARD receiver should be chosen in case of SIMS, MYMAS or other monitoring software types. 3. SYSTEM PROGRAMMING FROM RECEIVER MENU After completing instructions from Installer Manual it is time to start ENIGMA II monitoring receiver programming. The main settings can be done through the receiver menu displayed on LCD. The starting display, LED signals of monitoring receiver, and the functions without user code are shown in User Manual.
CONSOLE VER: CPM2.60.BC06 ENTER PASSWORD [ *█ ] ABCDEFG HIJKLMN OPQRSTU VWXYZ_ – F1 F2 F3 F4 Code entering is possible by choosing characters with F1 – F4 buttons (more pushes of one button can be used to change character, backspace is with ◄ button, code apply with ENTER button, exit with DISPLAY button). After code entering it is allowed to enter into receiver menu (without entering the code again) for 3 minutes since the last button pushing . 3.
F3 (RESET) Different level resets of the receiver unit. F1 (DEFAULT) – This function is to delete full event memory and set all settings back to default value. F2 (MEMORY) – This function is to delete full event memory, then receiver restart. F3 (RESET) – Receiver restart without deleting any events / settings. F4 (BACK) Navigation back with one menu level in receiver menu. 3.2 F4 (SETUP) menu OPTIONS PORTS TIME BACK F1 F2 F3 F4 F1 (OPTIONS) CONSOLE VER: CPM2.60.
• BUZZER OPERATE YES – ENIGMA II buzzer is on, yo can hear buzzer sound if there is new event until manual acknowledge (pushing ENTER button) / monitoring software acknowledge. NO – ENIGMA II buzzer is off, there is no buzzer signal in case of unacknowledged event. F2 (PORTS) / F1 (COM A) or F2 (COM B) CONSOLE VER: CPM2.60.
• RECEIVER ID The option has importance when there are more receivers connected to the same monitoring software. If each receiver has different number, in event list it can be seen which receiver sent the given event. • PORT SETTING You can check the actual serial port settings in this menu. Default values: 9600 (speed), 8, NONE (Data Bits & Parity) F2 (PORTS) / F3 (TCP/IP) In this menu you can configure the main monitoring receiver IP parameters and settings.
• NETMASK The used subnet mask in local area network. • GATEWAY This address is required if the device optionally wants to realize external communication (for example for WAN Test). Most of the times the gateway address is the same as rooter private (internal) address in local area network. • RECEIVE PORT (hexadecimal) The port can be defined where IP based (IP, GPRS) messages are coming to the monitoring station.
• CID TEST EVENT The test event code can be defined for CID communication. '0' character is displayed as 'A' character. • WEB HTTP PORT (hexadecimal) The device provides access for event list review through web browser. For this function this port should be configured. If you use different port as default 80, for view event list you should type the port as well after the IP address / domain name.
Note: After changing all kind of IP parameters please always restart the receiver unit. For this exit the menu, then F3 (UTIL) / F3 (RESET) / F3 (RESET). F3 (TIME) Date and time setting (function without password), details in User Manual. F4 (BACK) Navigation back with one menu level in receiver menu. 3.3 IP communication status menu From event list display it is possible to switch to IP communication status menu with long DISPLAY button push (3 seconds).
3.4 DISPLAY – card programming and status checking After pushing the DISPLAY button (DISPLAY LED lights continuously) you can enter into the following window: CARDS 1 2 3 4 5 6 7 8 RADIO OK OK ------------------------- 16:48:17 _ A OK I████████ B ----I USB A LPT AC OK –– OK COM-B IPLINK BATTERY R OK OK 1 : OK MON OFF SETUP STATUS HANG UP F1 F2 F3 F4 CARDS – Telephone line cards / IP cards status READY – Telephone line card / IP card is OK. RING – Ring on telephone line card.
3.5 DISPLAY / CARDS – telephone line card programming After DISPLAY button push (DISPLAY LED is steady) and choosing telephone line card (CARDS 1 – 8) it is possible to enter the chosen telephone line card settings menu with F2 (SETUP) button. CONSOLE VER: CPM2.60.
3.6 DISPLAY / RADIO – radio receiver card programming After DISPLAY button push (DISPLAY LED is steady) and choosing any of the radio channels (RADIO A – B) it is possible to enter the radio receiver card settings menu with F2 (SETUP) button. CONSOLE VER: CPM2.60.
Note: After changing radio receiver card parameters please always restart the receiver unit. For this exit the menu, then F3 (UTIL) / F3 (RESET) / F3 (RESET). Note: If you want to use more complex radio system (repeaters, more radio receiver units, two-way communication, etc.) please consult with your distributor. Note: After choosing the radio receiver card (RADIO A – B), with F3 (STATUS) button you can check the firmware version of the radio card (for example: RCM2.11.B223). 4.
In normal case programming of the monitoring receiver unit can be done in serial port (any of the COM ports or USB ports). After completing appropriate IP settings programming can be done through Ethernet network as well. Please use EniTerm software for programming. The programming steps are bellow: 1. Please start EniTerm software. Note: PC programming provides access for all system parameter settings. 2. Choose the ET (settings) file according to the device what you want to program: - CPM.
5. Please execute the required settings in EniTerm software. Note: The software functions are shown in EniTerm help menu. 6. Click to Communication / Write Data menu to send the modified settings to receiver. Note: Before reading LC telephone line card data, you should select number of the line card in the pop-up window. Note: During data reading (and sending) CPM firmware version can be checked. 5. TROUBLESHOOTING TROUBLE: Any abnormal operation in functions during the usage of the device.
TROUBLE: After proper IP configuration receiver events are not coming through IP. SOLUTION: Don't forget to allow used ports in rooter (Port forward menu in rooter). TROUBLE: Event names are missing, or not correct in receiver display. SOLUTION: Because of the new functions there might be new menus and events in receiver, so receiver language should be updated regularly (see Firmware upgrade). TROUBLE: There are strange internal messages in receiver with 0000 client account.
6. ENIGMA II TESTING When all setting is finished it is possible to test ENIGMA II unit. Testing is also useful to test data sending from an external installation place. The testing software in the given local network can help a lot to check monitoring transmission and find the reason of possible problems. For test please use ipt.exe software in the following way: 1. Enter the IP address or Domain name of the monitoring station. 2.
Received events in Enigma II can be checked easily with a simple web browser access. For this IP address (and port if it is different from 80) of Enigma II unit should be typed in a web browser (Internet Explorer recommended). Then all received events from receiver memory can be seen. Note: For the operation of event list review through web browser the IP ADDRESS and HTTP PORT should be enabled in rooter as well. Note.: Web browser access can be limited with password generated by wpg.exe software.
7. FIRMWARE UPGRADE AND OTHER FUNCTIONS It is recommended to upgrade regularly CPM card (basically the receiver itself) firmware, LC card (telephone line receiving unit), IP card (IP extension card) and RC card (radio receiver unit) firmware to use new functions and eliminate possible bugs. Firmware upgrade can be done by the following steps: 1. Get the latest firmware files from your distributor (CPM / LC / IP / RC). 2.
CPM – CPM card (cpm.bot) programming; CPM Data – Receiver menu language (cpm.bin) / Web browser menu (cpm.dat) / Web logo (.jpg) update; LC Tel. Line Card – Telephone line card (lc.bot) upgrade; IP Card (USB) – IP extension card (ip.ipx) upgrade – Not possible through CPM! RC, LRR2 – Radio Card – Radio repeater device firmware upgrade. 5. The following window will pop up if you use IP Card update. 6. Choose the proper firmware file for upgrade (2. STEP), then NEXT.
Note: If there is any problem during CPM firmware update (current blackout, cable remove, other), repeat the upgrade steps from 3. point (start Enigma II Uploader). If there is any problem during update steps, you can try the following: • After choosing COM port (6. point, 3. STEP) choose the Selected Speed (Without checking) option, and set speed to 57600. • Turn off the power supply of ENIGMA II unit.
8.
System Message Code Description LINE CARD RESET E0 Line card restarted TEL LINE ERROR 20 Telephone line error TEL LINE OK 30 Telephone line restored FAULT CALL 40 Received call error, no data receiving FAULT DATA 10 Received data error, missing data CANCEL CALL 50 Call abort by the user (hang up) LINE CARD FAIL D0 Internal communication trouble with line card System Message Code DATAFILE MODIFY B1 IP receiver card web browser data file modified SETTING MODIFY B2 IP receiver ca
9. COMPATIBILITY ENIGMA II receiver is compatible with the following communicators and monitoring software types: Monitoring software • ALARM SYS (recommended) • SIMS • MYMAS SURGARD receiver should be chosen in case of SIMS, MYMAS or other monitoring software types.
9.