User manual

BUZZER OPERATE
YES ENIGMA II buzzer is on, yo can hear buzzer sound if there is new event until
manual acknowledge (pushing ENTER button) / monitoring software acknowledge.
NO ENIGMA II buzzer is off, there is no buzzer signal in case of unacknowledged
event.
F2 (PORTS) / F1 (COM A) or F2 (COM B)
CONSOLE VER: CPM2.60.BC06
SERIAL PORT A
OPERATION MODE NORMAL
RECEIVER ID 01
PORT SETTING 9600, 8, NONE
+ PAGE CANCEL
F1 F2 F3 F4
It is recommended to modify the following settings only:
OPERATION MODE
NORMAL ENIGMA II forwards data on the given port towards monitoring software
(default port for PC connection).
RECEIVE ENIGMA II can only receive data on the given port (this port is to connect
another receiver to ENIGMA II, or for reserve port).
Note: COM A and USB A ports are equivalent, as the COM B and USB B ports. Do not
connect devices at the same time to COM A and USB A ports. If it is possible, always
recommended to use COM A as against USB A.
Note: If the A serial port of the receiver has any trouble, B port can work as a
replacement. For this switch on OPERATION MODE to RECEIVE on port A, and to
NORMAL on port B. Please connect PC connector from port A to port B.
9