Owner`s manual

Wood Wine Cabinet Owners Manual
16
VINOTEMP.COM
CLEARANCE GUIDELINES
It is very important that you place your cabinet in a well ventilated area. Otherwise, heat
exhausted by the condenser will build up and the cooling system will not operate
properly.
1) Rear Exhaust Location
Leave min. 6 inches
clearance from the rear to the
wall.
Leave min. 12 inches
clearance from the top to the
ceiling.
Leave min. 6 inches
clearance from the left and
right sides.
2) Front Exhaust Location
Leave min. 6 inches
clearance from the front if left
and right sides are
unobstructed.
Or, leave min. 36 inches
clearance from the front if left
and right sides are obstructed
3) Top Exhaust Location
Leave min. 12 inches
clearance from the top to the
ceiling.
Leave min. 2 inches
clearance from the rear to the
wall.
Leave min. 2 inches
clearance from the left and
right sides.
EXAMPLE WITH STANDARD R E A R E X H A U S T L O C A T I O N :
4) Side Exhaust Location
Leave min. 6 inches clearance from the left or right side to the wall.
Leave min. 12 inches clearance from the top to the ceiling.