Specifications

On initial start-up the system will slowly reduce the temperature of the enclosure. The
system may run constantly or cycle on and off frequently until the enclosure reaches the desired
temperature. The time needed will very depending on size, contents, and construction. The thermostat
is preset for approximately 55f. Unless the temperature falls below what is desired, do not change
the setting for at least 3 days. After initial cool down the on-off cycle should be relatively constant.
VINO-2500SS
FAN COIL 2500BTU R-134A ETL & NSF LISTED 35LBS
CONDENSING UNIT UL LISTED 40LBS
VINO-4500SS
FAN COIL 4500BTU R134A ETL & NSF LISTED 40LBS
CONDENSING UNIT UL LISTED 46LBS
VINO-6500SS
FAN COIL 6500BTU R134A ETL & NSF LISTED 90LBS
CONDENSING UNIT UL LISTED 66LBS
VINO-8500SS
FAN COIL 8500BTU R134A ETL & NSF LISTED 115 LBS.
CONDENSING UNIT UL LISTED 95LBS
25' 50' 100'
VINO-2500SS 2500BTU 500CUFT 900 BOTTLES 3/8 X 1/2 3/8 X 1/2 3/8 X 1/2
VINO-4500SS 4500BTU 1000CUF
T
4500 BOTTLES 3/8 X 1/2 3/8 X 1/2 3/8 X 5/8
VINO-6500SS 6500BTU 1500CUF
T
6000 BOTTLES 3/8 X 1/2 3/8 X 5/8 3/8 X 5/8
VINO-8500SS 8500BTU 2000CUF
T
10000 BOTTLES 3/8 X 5/8 3/8 X 5/8 3/8 x 7/8
ELECTRICAL BOX
C D
B
DRAIN
A B C D DRAIN
VINO-2500SS 17.5 7.5 20 21.5 3/8 OD
VINO-4500SS 17.5 10.5 20 21.5 3/8 OD
VINO-6500SS 21 11.75 29.875 30.375 3/4 MPT
VINO-8500SS 21 13.5 29.875 30.375 3/4 MPT
H
D
WHD
VINO-2500SS 10.75 9.43 15.08
VINO-4500SS 10.75 9.43 15.08
VINO-6500SS 13 10.88 17.25
VINO-8500SS 14.6 13.75 18.5
FAN COIL DIMENSIONS
FAN
BOTTOM VIEW
OPERATION
A
SIDE VIEW
115V 60HZ 1A
SPECIFICATIONS
115V 60HZ 5.7A
115V 60HZ 12A
115V 60HZ 1A
115V 60HZ 1.5A
115V 60HZ 6.9A
W
115V 60HZ 5.2A
LINE SET
FAN COIL
208-230V 60HZ 1PH 7.3A
CONDENSING UNIT