Service manual

- 23 -
condensate
c. Evaporator air flow restriction
d. Water passages restricted
e. Drip tray leak (No water overflow
but water leak)
c. Check supply air flow or air TD
d. Clean the drip tray
e. Seal the leak using silicone sealant
15.Excessive
condensate
in wine
cellar
a. Air leak in the wine cellar causing
excessive condensate
b. High humidity causing excessive
condensate
c. Water passages restricted
a. Check for any air leak
b. Use drain line
c. Clean the drip tray
16.Circuit
tripping
a. Incorrect fuse or breaker
b. Incorrect wirings
c. Failed components
a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service
17.Noisy
operation
a. Mounting area not firm
b. Loose parts
c. Compressor overloaded due to
high ambient temperatures or
airflow restriction
d. Defective components
a. Add support to improve installation
b. Check fan blades, bearings,
washers, tubing contact and loose
screws.
c. Check for airflow
d. Call service for checking internal
loose, inadequate lubrication and
incorrect wirings