Use and Care Manual
- 10 -
Fig. 2.7 CABINET GRILLE
2. VINO3500-8500HZD THROUGH WALL INSTALLATION
• Cut a rectangular opening at the wine room wall as illustrated. The
dimensions of the opening shall be 1/4” larger than the width and height of
the unit.
• If top exhaust, cut another rectangular opening at the top of the cabinet to
the length and width of the top exhaust.
• Construct a shelf as shown. The shelf must be capable of supporting the
weight of the unit.
• Place the unit on the shelf with the back of unit flush with the outside of
the wall.
• Attach the wall grille to the outside wall with screws.
• Seal the area between the cooling unit and opening with a high quality
weather stripping or polyurethane spray foam and cover with molding.
• If top exhaust, place another gaskets along the top exhaust at the top of
the cooling unit (see Fig.2.9).