the compressor
c. Check start relay, start
capacitor, overload protector,
and compressor
d. Call service at 1-800-
777-VINO for OEM
information
Compressor
running but fan is
not
a. Fan blade bond
b. Incorrect or loose
wiring
c. Failed motor
a. Check for proper fan blade
clearance
b. Check all wiring
c. Call service at 1-800-
777-VINO
Wine-Mate unit is
not cooling but
the compressor
and fan continue
to run
a. Evaporator’s airflow is
restricted
b. Refrigerant is leaking
c. Refrigeration system
is restricted
a. Check for airflow through
evaporator
b. Check for loss of refrigerant
c. Call service at 1-800-
777-VINO to check for
restrictions
Temperature is
too high or the
Wine-Mate unit is
running too long
a. Improper evaporator
or condenser air flow
b. Dirty condenser
c. Iced evaporator
d. Malfunctioning fans
e. Improper seals
f. Area to be cooled is
too large for the
current Wine-Mate
unit
g. Low voltage
h. Operating 60 Hz unit
at 50Hz
i. Sealed system
problem
j. Undercharge or
overcharge
a. Check for air restrictions
b. Clean the condenser
c. Defrost the evaporator and
reset the temperature
d. Check both fans
e. Check gasket and door
opening
f. Check for excessive load or
incorrect installation
g. Check power supply
h. Use proper 60 Hz
i. Call service at 1-800-
777-VINO if there is loss of
refrigerant or restrictions
j. Call service at 1-800-
777-VINO to add or remove
refrigerant
House circuit
tripping
a. Incorrect fuse or
breaker
b. Incorrect wiring
c. Failed components
a. Check for proper fuse or
breaker
b. Check all wirings and
connections
c. Call service at 1-800-
777-VINO