Specifications
- 8 - 
Temperature and Humidity 
1.  Use of the controller 
Fig. 3.1 TEMPERATURE CONTROLLER 
1) Keys 
SET: To display target set point; in programming mode it selects a parameter or 
confirm an operation. 
(DEF): To start a manual defrost. 
(UP):  To see the maximum stored temperature; in programming mode it 
browses the parameter codes or increases the displayed value. 
 (DOWN): To see the minimum stored temperature; in programming mode it 
browses the parameter codes or decreases the displayed value. 
: To turn on/off the power to the unit. 
+ : To lock/unlock the keypad. 
SET+ : To enter in the programming mode. 
SET+ : To return to the temperature display. 
2) Lock and unlock the keys 
To lock the keys, press up + down keys  +  until POF is displayed; to unlock 
the keys, press up + down keys  +  until PON is displayed. 
3) Display 
During  normal  operating  conditions,  the  display  shows  the  value measured  by 
the  air  regulation  probe.  In  case  of  active  alarm,  the  temperature  flashes 
alternately to the code alarm. The LED functions are listed as follows. 
LED 
MODE 
FUNCTION 
ON 
Compressor enabled 
Flashing 
Anti-short cycle enabled 
ON 
Defrost cycle enabled 
ON 
Fan enabled 
Flashing 
Fan delay after defrost enabled 
ON 
Alarm occurring 
ON 
Temperature measuring unit 
Flashing 
Programming mode 