Extreme 8000 Duct Kit by Vinothèque and WhisperKOOL® “Protecting Your Investment in Fine Wines”
Extreme Duct Kit Parts List DuctingAdapter x 1 or 2 10inch to 8inch reducer x 1 or 2 18 inches 18 inches 62 inches
Installation Step 1: Remove the grill from the unit by unscrewing the four screws that hold it in place.
Installation Step 3: Screw the Duct Kit into place using the same screws that held the grill in place.
Ducted Installation Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only insulated ductwork to minimize cooling losses, prevent sweating, and reduce noise. Use ductwork on the condenser section to redirect or absorb sound, bring in outside air to the unit inlet, and/or exhaust the hot air out of the ambient space. Note: Do not exceed a total of 25’ for each length of ductwork run and a total of 50’ combined for both the supply and return lengths.
Using Ductwork Cold Air to/from Wine Cellar Remove supply air grille to install ductwork between WhisperKOOL Extreme unit and the cellar. Connect the supply air ductwork from the cellar to the supply air outlet adapter flange at the WhisperKOOL Extreme unit. Connect the return air ductwork from the cellar to the return air inlet adapter flange at the WhisperKOOL Extreme unit. Warm Air to/from Wine Cellar Connect ductwork on the condenser to direct heat and air noise away from occupants.
Standard Ducted Installation Dual Outlet Duct Outside through the Wall 25
Remote Mount on Floor Outside Remote Mount 26
Attic Mounted System