TUSCANY Plus WINE CELLAR ASSEMBLY & OPERATION MANUAL ~1~ 110 220
~2~
READ BEFORE YOU START 1. LOCATING YOUR WINE CELLAR - Remember, it is not only an appliance but also a piece of furniture A. Provide 4” minimum clearance for both sides and back, keep the top completely clear. Under no circumstances should the unit be “built-in” in any way. B. Never locate your wine cellar outdoors or in an area with extremes of temperature and humidity. Garages, attics, unfinished basements, laundry rooms, breezeways, closets or any unventilated room.
HARDWARE KIT A Cam Cap x 20 (x24)* D Hex wrench x1 B C Phillips Bolt x2 Hex bolt x 14 E F Cam x 20 (x24)* Cam Pin x 20 (x24)* G H Hinge x2 Leg x4 K I J Washer x1 Rubber Grommet x2 Panel Insulation Strip x1 *NOTE : Hardware quantities for Model 220 are indicated in parenthesis.
STEP 1 : PANEL PREPARATION CAUTION : K 1. Watch for sharp staples on boxes. 2. DO NOT STEP ON PANELS 3. The manual will give a recommended order to open boxes, it saves space and time. PANEL EDGE K K Open Box V1. 1 Install INSULATION STRIP to Back, Top, and Bottom Panels. PUSH IN FULLY! 2 Insert Cam Pins (F) in BACK PANEL’S pre drilled holes.
STEP 2 : CABINET ASSEMBLY 1 Attach Top and Bottom to Back by CAREFULLY aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. DO NOT BANG OR SLAP PANELS TOGETHER!!! 2 Insert Cam and make sure Arrow points to outside edge. Gently push down to bring panels together before you tighten the Cam. Cam Arrow faces away from outside edge when tightened.
STEP 2 : CABINET ASSEMBLY CONTINUED Open Box V5 or V2. 1 2 Insert Cam Pins (F) into SIDE PANEL’S pre drilled holes both sides. Attach SIDES to Back/Bottom/Top by Carefully aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. DO NOT BANG OR SLAP PANELS TOGETHER!!! Insert Cam, Push Panels together before tightening Cam. TOP !!! F TOP PANEL can be identified by two Threaded Holes A 3 ~7~ Insert Cam Cap (A) in all Cam Holes.
STEP 3 : HINGE,BASE AND LEGS INSTALLATION 2 1 H Fasten one HINGE (G) to the SIDE of the cabinet NOTE : Hinge can be on either side of the cabinet. 2 Install four LEGS (H) into BASES fully in.
STEP 4 : SHELVES 1 Open box V4 Hook SHELVES into hangers starting from the bottom of cabinet PRESS 1 TOP 1 2 BOTTOM HINT : CA BO B I N TT E T OM ~9~ 1 Snap SHELVES into hangers on one side 2 Push the SHELVES down to snap into opposite side hangers
STEP 5 : COOLING UNIT INSTALLATION 1 Screw in Bolt (B) and Rubber Grommet (J) into top panel until grommet touches top. DO NOT compress Grommet. LEFT SIDE ONLY! J B K O PH OO B E N 2 J ATTENTION!!! SERIAL NUMBER PLEASE WRITE DOWN THE SERIAL NUMBER ON THE WARRANTY REGISTRATION FORM.
STEP 5 : COOLING UNIT INSTALLATION CONTINUED 3 Slide unit into the back opening and lock the HOOK WING over the LEFT BOLT and GROMMET from (STEP 1). Top View OK O EB N O PH 4 ~11~ Screw in Right Bolt into top panel until grommet touches top. DO NOT compress Grommet.
STEP 5 : COOLING UNIT INSTALLATION CONTINUED 5 6 Insert Drain Cup by angling the Drain Cup inserting back tab first then push in front lip to allow tab in. Insert Air Deflector to back of cooling unit. Install bottom Tab first.
STEP 5 : COOLING UNIT INSTALLATION CONTINUED NOTE: If unit is operated according to specifications overflows will not occur. Excess condensation is only caused by extreme conditions. Unit will shut off at 72 °F and will restart when temperature drops or unit is repluged. (In this case insert hose to drain hole, cut to appropriate length.) CAUTION : Maximum Total Load: 1A Use only with certified light fixture. Container Optional (not required) except as emergency drain.
STEP 6 : LIGHT AND LIGHT COVER INSTALLATION 1 Fasten LIGHT CLIPS into mounting holes predrilled on front edge of TOP panel 4 5 Snap LIGHT in LIGHT CLIPS Plug small end of power cord into socket on side of light Snap LIGHTCOVER over the LIGHT HINT: To hide excess light cord, tuck into top space of cooling unit. NOTE : To replace the light bulb: 1. Press down on ends of light behind to release cover. 2.
STEP 7 : DOOR INSTALLATION 1 Open box V3 Place WASHER (I) on BOTTOM HINGE (G) 2 Insert DOOR onto BOTTOM HINGE (G) 2 I 1 G D 3 C 3 G Install TOP HINGE (G) with HEX BOLTS (C) NOTE : ~15~ Adjust final position of the door before tightening the bolts
CONTROLS : FEATURES: - OPERATION: PLUG IT IN (wait one minute) and ENJOY! Default SET temperature 57º F/14º C (ideal for wine storage). DISPLAY: Calibration option of the temperature sensor. SET temperature range 52ºF-72ºF. Digital temperature sensor. Dual display Fº/Cº. Magnetic overflow sensor. Settings are stored in memory for power failures. Pre programed software will reach the quietest most efficient operation.
MAXIMUM CAPACITIES AND LOADING TIPS Maximum capacities and sample loading arrangements for Vintage Keeper Tuscany wine cellars are illustrated below. Note the variations in shelf height, to accommodate the widest variety of bottle types and sizes. Standard Burgundy and Bordeaux bottles are best arranged with necks facing out; some taller bottles may need to be arranged neck to neck. Never stack bottles more than two rows high on a shelf; all shelves must be installed as directed.
TROUBLE SHOOTING GUIDE Although each Vintage Keeper cooling unit has been carefully tested at every stage of manufacture, occasional problems arise, the majority of which are due to rough or careless handling during shipping or installation. Other problems may derive from improper cabinet assembly, power interruption or surge, low line voltage (less than 105V), or failure to clean the unit regularly (see illustration below).
LIMITED WARRANTY AND PRODUCT SUPPORT ONE YEAR LIMITED WARRANTY If your Vintage Keeper cooling unit or cabinet fails to perform as designed within one year of the date of purchase, VINTAGE KEEPER INC. warrants that, upon your request, it will be repaired or replaced, at our option, during the one year warranty period. This warranty applies only to the first end-user purchaser of a Vintage Keeper unit that is purchased and used in the continental United States or Canada (excludes Alaska and Hawaii).
TUSCANY Plus WINE CELLAR 5648 McAdam Rd., Mississauga ON CAN L4Z 1T2 Phone : 905.501.8582 Fax : 905.501.0889 Toll free: 1.888.274.8813 customerservice@vintagekeeper.com www.vintagekeeper.