Armoire à vin Beverage Preservation Technology USER MANUAL V40BVC AL/S3/BK V20BVC S3/BK V20BVC V26BVC code: VIM 201604/BVC/01
WARNING The information in this document is subject to modification without any prior notice. Somes models are available in dedicated countries only. . VINTEC offers no guarantee for our Beverage Center if it is being used for any purpose other than that for which it was specifically designed. VINTEC cannot be held responsible for any error in this manual.
• The room for installing the appliance must be at least 1 cubic metre per 8 grams of refrigerant. The refrigerant quantity contained in this appliance is listed above in grams; it is also noted on the Rating Plate of the appliance. It is hazardous for anyone other than an Authorised Service Person to carry out servicing or repairs to this appliance. – WARNING: Keep ventilation openings in the appliance enclosure or in the built-in structure clear of obstruction.
The Beverage Center should be placed where the ambient temperature is between 5ºC to 35ºC. If the ambient temperature is above or below this range, the performance of the unit may be affected. Placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate. The ideal range of temperature may not be reached. (See Climate Class at the end of this manual) Grounding instructions The Beverage Center must be grounded in case of an electrical short circuit.
IMPORTANT - THIS SPACER MUST BE ATTACHED TO THE UNIT BEFORE INSTALLATION FOR VENTILATION PURPOSE. FAILURE TO DO SO VOIDS THE WARRANTY TURNING ON YOUR BEVERAGE CENTER Plug in and switch on the unit by pressing on the power button for a few seconds. When you use the Beverage Center for the first time (or restart the Beverage Center after having it shut off for a long time), there will be a few degrees, variance between the temperature you have selected and the one indicated on the LED readout.
Operating Noises To reach the desired temperature settings, VINTEC Beverage Center, like all Beverage Centers operating with compressors and fans, may produce the following types of noises. These noises are normal and may occur as follows: - Gurgling sound - caused by the refrigerant flowing through the appliance’s coils. - Cracking/popping sounds -resulting from the contraction and expansion of the refrigerant gas to produce cold. - Fan operating sound - to circulate the air within the Beverage Center.
TYPES OF REGULATION Please note that, depending on the loading and settings chosen, it takes about 24 hours for the Beverage Center to see the temperature stabilizing. During this time LED seems to move erratically. It is normal and this process occurs whenever the setting is modified and/or whenever a large amount of bottles are added to the unit. TEMPERATURE SETTINGS Important: The LCD displays, by default, the actual internal air temperature.
Internal light In order to reduce energy consumption, this wine cabinet will automatically switch off the LED lights after 10 minutes. If you want the LED light to remain on continuously, this is possible. Please press and hold the "LIGHT" button for 5 seconds, the display will show "LP".After 4 seconds the display will revert back to normal and the light will remain on until manually switched off.
REVERSIBILITY OF THE DOOR Warning: To avoid accidents during the process of changing the door, we recommend that you get assistance. The glass door is heavy and may cause injury if dropped. - Depending on to the model and the type of handle your wine cabinet is equipped with, you may have to rotate the door through 180 degrees.
- While holding the door firmly, remove the three lock screws (2) from the lower right hinge module, and remove it.(Fig.1) - Remove the three lock screws (4) from the top right hinge and remove the hinge (3) . (Fig.3) - Fix the top left hinge (5) at the top left corner with the three lock screws (4) . (Fig.4) - While holding the door, insert the axis core into the door’s (7) upper left hinge hole. Fix the left bottom hinges by inserting the axis core first into the door’s lower left hinge hole (6).
4. Remove decorative nail (8) from left top of cabinet and install spare top hinge (Left) (7) at left top of cabinet with 3 screws. (Fig. D) 5. Following the above procedure, install the spare lower hinge to the left (9). (Fig. E) 6. Install and aligned the door. 7. Insert the plastic caps to cover the holes(8). V26BVC &V20BVC /S3/BK 1 Lock screws 4 Top hinge (Right) 7 Top hinge (Left) 2 Lower hinge (Right) 5 Door 8 Lower hinge (Left) 3 Door axis 6 Cabinet body - Unscrew the lock screws (1); (Fig.
If it is left hinge,reverse the door as the same way. V40/V26/V20 SERIES UNDER-BENCH INSTALLATION INSTRUCTIONS 1. Vintec beverage Center dimensions: V40 Height 820mm – 860mm (40mm adjustable feet) Width 595mm Depth 571mm + 30mm stopper (Total of 601mm) V26 Height 820mm – 830mm (10mm adjustable feet) Width 380mm Depth 572mm + 30mm stopper (Total of 602mm) V20 Height 810mm – 830mm (10mm adjustable feet) Width 295 – 300mm Depth 561– 592mm + 30mm stopper (Total of 622mm) 2.
VENT SPECIFICATIONS Front View (V40) Front View (V26) Front View (V20) 400mm 12 code: VIM 201604/BVC/01
Front View (V20) Front View (V20) 400mm 320mm Cross section 30 mm * This applies to all V40&V20BVC BK&S3 models. * only 10mm requires for V26&V20&AL-V40BVC etc.
5. This Vintec Beverage Center is front venting. The cabinet draws air from the front and rear and expels through the grill under the door at the front. If a joinery kick board is being placed in front of the Beverage Center, a grill of at least the same width as the Beverage Center grill and with a minimum airflow allowance of 150cm2 must be installed into the kick board. 6. This unit has a power switch located on the control panel. Power point location is therefore not critical. 7.
615 595 555 525 10 525 555 820 850 30 30 30 Dimensional drawings: V40BVC S3/BK 10 10 10 30 Front View 31 Top View Side View 555 525 10 525 555 30 30 615 595 820 830 10 AL-V40BVC 10 10 10 Front View 30 31 Side View 15 Top View code: VIM 201604/BVC/01
V26BVC V20BVC 16 code: VIM 201604/BVC/01
315 295 554 524 10 10 Front View 524 554 820 850 30 30 30 V20BVC S3/BK 30 Side View Top View OPERATION ANOMALIES Ensure that there is power to the electrical supply plug by connecting another electrical appliance to it. Check fuse, if any. Make sure that the door is closed properly. If your beverage center appears to be malfunctioning, unplug it and contact your VINTEC’s after sales service.
Irrespective of the cause, if you notice either abnormal temperature or humidity levels inside your beverage center, be reassured that only long and frequent exposure to these abnormal conditions can cause a detrimental effect on your beverage. TROUBLESHOOTING GUIDE Common problems may easily be solved, saving you the cost of a possible service call. Please read carefully the instruction manual and revert to troubleshooting guide chart. PROBLEM Beverage center does not operate.
Technical data Models Capacity 355ml Net capacity Gas charge quantity Pre-set temp in degrees Adjustable temp in degrees Power Input Heater (0) Freestanding or Built-in Nº of shelf: (1) Ambient temp in degrees Net dim in mm WXDXH Gross dim in mm WXDXH(2) Net weight Gross weight REFRIGERANT AL/S3/BK V40BVC (R600a) 140 146 L 35 g 5 2-10ºC 100W -Built-in 3 5-35ºC 595x572x820 655x665x875 44 kg 48 kg R600a V26BVC (R600a) V20BVC (R600a) 74 81.
Standard features: Compressor operated: R600a - Available in rated voltage/frequency (as per country's requirements): 100V/50/60Hz, 220V/50/60Hz,115V/50Hz - Automatic defrost - Humidity : 65% RH +/-10% RH - Black outer and inner finish - Internal light - Adjustable feet x 4 - Double glass door with 3rd acrylic layer - Seamless Stainless Steel door frame finish for “S3” models 20 code: VIM 201604/BVC/01
Copyright: All rights are reserved. All photocopying, reproduction, translation whether partial or total are strictly prohibited, without prior written consent from VINTEC. www.vintec-cellar.