Armoire à vin.
WARNING The information in this document is subject to modification without any prior notice. VINTEC offers no guarantee for our Beverage Center if it is being used for any purpose other than that for which it was specifically designed. VINTEC cannot be held responsible for any error in this manual. VINTEC is not responsible or liable for any spoilage or damage to beverage or any other contents incidental or consequential to possible defects of the Beverage Center.
It is hazardous for anyone other than an Authorised Service Person to carry out servicing or repairs to this appliance. In Queensland the authorized person must hold a Gas Work Authorisation for hydrocarbon refrigerants, before carrying out servicing or repairs which involve the removal of covers. – WARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction.
The Beverage Center should be placed where the ambient temperature is between 5ºC to 35ºC. If the ambient temperature is above or below this range, the performance of the unit may be affected. Placing your unit in extreme cold or hot conditions may cause interior temperatures to fluctuate. The ideal range of temperature may not be reached. (See Climate Class at the end of this manual) Grounding instructions The Beverage Center must be grounded in case of an electrical short circuit.
IMPORTANT - THIS SPACER MUST BE ATTACHED TO THE UNIT BEFORE INSTALLATION FOR VENTILATION PURPOSE. FAILURE TO DO SO VOIDS THE WARRANTY TURNING ON YOUR BEVERAGE CENTER Plug in and switch on the unit by pressing on the power button for a few seconds. When you use the Beverage Center for the first time (or restart the Beverage Center after having it shut off for a long time), there will be a few degrees, variance between the temperature you have selected and the one indicated on the LED readout.
Operating Noises To reach the desired temperature settings, VINTEC Beverage Center, like all Beverage Center operating with compressors and fans, may produce the following types of noises. These noises are normal and occur as follows: - Gurgling sound, caused by the refrigerant flowing through the appliance’s coils, - Cracking/popping sounds, resulting from the contraction and expansion of the refrigerant gas to produce cold, - Fan operating sound, to circulate the air within the Beverage Center.
TYPES OF REGULATION Please note that depending on the loading and settings chosen it takes 24hours for the Beverage Center to see the temperature stabilizing. During this time LED seems to move erratically. It is a normal process. This process occurs whenever the setting is modified and/or whenever a large amount of bottles are added to the unit. TEMPERATURE SETTINGS Important: The LCD displays by default the actual internal air temperature.
DEFROSTING/CONDENSATION/ HYGROMETRY/ VENTILATION Your beverage center is designed with “Auto-cycle” defrost system. During “Off-cycle” the refrigerated surfaces of the beverage center defrost automatically. Defrost water from the beverage center storage compartment drains automatically and part of it goes into a drainage container, which is located at the back of the beverage center next to the compressor.
REVERSIBILITY OF THE DOOR Warning: To avoid accident during the process of changing the door, we recommend that you get assistance. Door is heavy and may cause injury if dropped. According the model and the type of handle your beverage cabinet is equipped with, such as long strait bar handle , the door might needs to be rotated for 180 degrees or changed for a right opening one.
INSTALLATION INSTRUCTIONS AND DRAWINGS 1. Wine Cabinet dimensions : Height 820mm – 860mm (40mm adjustable feet) Width 595mm Depth 571mm 2. This wine cabinet is not designed to be fully integrated behind a joinery door. 3. Please note that a minimum cut out of 615mm is required to facilitate installation, removal and servicing. 4. This wine cabinet requires 10mm clearance on both sides and top, 30mm clearance at the rear.
Dimensional drawings: OPERATION ANOMALIES Ensure that there is power to the electrical supply plug by connecting another electrical appliance to it. Check fuse, if any. Make sure that the door is closed properly. If your beverage center appears to be malfunctioning, unplug it and contact your VINTEC’s after sales service. Any intervention on the cold circuit should be performed by a refrigeration technician who should carry out an inspection of the circuit sealing system.
TROUBLESHOOTING GUIDE Common problems may easily be solved, saving you the cost of a possible service call. Please read carefully the instruction manual and revert to troubleshooting guide chart. PROBLEM Beverage center does not operate. Beverage center is not cold enough. Turns on and off frequently. The light does not work. Vibrations. The Beverage center seems to make too much noise. The door will not close properly. POSSIBLE CAUSE Not plugged in. The appliance is turned off.
Technical data Models Capacity355ml Net capacity Gas charge quantity Pre-set temp in degrees Adjustable temp in degrees Power Input Heater Freestanding or Built-in No.
Copyright: All rights are reserved. All photocopying, reproduction, translation whether partial or total are strictly prohibited, without prior written consent from VINTEC. www.vintec-cellar.