User manual
8
TEMPERATURE SETTINGS
Important: The LCD displays by default the actual internal air temperature.
The temperature settings are pre-set at the factory as follows. In the event of a power
interruption, all previous temperature settings are automatically erased and it will revert to
the preset temperature settings.
Factory preset chart
Model Setting Temperature
V30 / V50 SG
Normal
10ºC -14ºC
V30 / V40/ V50 SG "e"
12
12ºC (+/- 2.5ºC)
Upper compartment: 6 6ºC (+/- 2.5ºC)
V30/ V40 / V50 SG "2e"
Lower compartment: 12 12ºC (+/- 2.5ºC)
Left compartment: 12 12ºC (+/- 2.5ºC)
V40/50 DG "2e"
Right compartment: 7 7ºC (+/- 2.5ºC)
It is important to understand that there is a difference between the air temperature inside
the wine cellar and the actual temperature of the wine: You will need to wait
approximately 12 hours before noticing the effects of temperature adjustment due to the
critical mass within a full wine cellar.
Once the thermostat is set, it is strongly advised not to toy with it or adjust frequently. The
thermostat will maintain the temperature inside the wine cellar within a +/- 2.5ºC range.
But the thermal inertia of the wine and the glass is such that within this temperature range,
the actual temperature of the wine will only fluctuate 0.5ºC to 1ºC.
Standard models:
“MAX” adjustable from 5 to 9 ºC
“NORMAL” adjustable from 10 to 14 ºC
“MIN” adjustable from 15 to 18 ºC