User's Manual

UNDER-BENCH INSTALLATION INSTRUCTIONS
INSTALLATION
5
User Manual
Front View (VWS020SBA-X / VBS020SBA-X)
DIMENSIONS:
VWS020SBA-X/VBS020SBA-X
Height 820mm – 870mm (50mm adjustable feet)
Width 295-300 mm
Depth 561mm + 30mm stopper (Total of 591mm)
For VWS020SBA-X/VBS020SBA-X
a minimum cut out width of 320mm is required to
facilitate installaon, removal and servicing.
1. Vintec “Built in” Wine Cellar and Beverage Centres
are front venng but are not designed to be fully
integrated behind a joinery door.
2. Vintec “Built in” Wine Cellar and Beverage Centres
require 10mm clearance on both sides and 30mm on top,
30mm clearance at the rear (Back spacer is provided), to
facilitate installaon, removal, servicing and venlaon.
INSTALLATION DRAWINGS FOR fornt venng under
bench Wine Cellars and Beverage Centres:
3. Vintec Built in Wine Cellar and Beverage Centres
draw air from the rear and expels it through the metal
grid under the door at the front. If a kick board is to be
placed in front of the Wine Cellar and Beverage Centre’s
grid another one must be fied into the kick board with
a minimum air flow allowance of 150cm².
4. Vintec “Built in” Wine Cellar and Beverage Centres have
a power switch located on the control panel so power
point locaon is not crical.
5. The Wine Cellar and Beverage Centre requires a
standard 240 volt/10 amp power point. (Or according
to different countries specificaons).
6. The power cord is 1.9m in length and is fixed on the
right side at the back when looking from front of cabinet.
7. As with most appliances of today, the Wine Cellar and
Beverage Centre has sensive electronic components
which are suscepble to damage through lightning and
electricity supply faults. It is therefore advised to use a
power surge protector to avoid problems of this nature.
8. Air vent within the joinery must be provided for Vintec
built in Wine Cellar and Beverage Centres (Front venng)
In Hot climate zone, an air vent or grid, with a minimum
venlaon size of 200mm x 40mm MUST be cut out at
the rear top of the back paroning or at the top of either
side of the paroning, allowing cool fresh air full access
This air vent or grid must not be opened on the same
side as other appliances such as ovens or an area that
is sealed and without access to fresh cool air. Failing
to comply with the above specificaons could result
in WARRANTY void.
to flow into the 30mm gap located at the rear of the
cabinet.
min width
Cross secon
Suitable pointe for venlaon grid.
Nite: only one vent is required.
Dimensional drawings:
VWS020SBA-X / VBS020SBA-X
295
30
850
820
10
10
Front View
315
524
30
30
554
Side View
30
554
524
Top View
30mm