Balance mechanism digital display calibration
The digital display (15) indicates the setting of the balance mechanism on a scale of 0 (minimum
setting) to 100 (maximum setting). In the unlikely event of this system requiring calibration, pro-
ceed as follows:
Level the platform and apply centre lock (7).
Press and hold both buttons (14)(16) until CAL is displayed on the top row of the display.
Push in and turn the balance knob (8) counterclockwise until its minimum end stop is
reached, then turn back two full turns. The bottom row of the display will flash 0.
Press and release the timer button (14). The bottom row of the display will flash 100.
Push in and turn the balance knob (8) clockwise until its maximum end stop is reached, then
turn back two full turns.
Press and release the timer button (14). Calibration is now complete and the display will
revert to the default clock mode.
After calibration, rebalance the head (see “Balancing the head” on page 12).
NOTE: If more than five minutes is allowed to elapse before completion, the system
will shut down and revert to its previous settings.