Operating Voltage
Fuse Rating Fuse Size
100V, 110V or 120V T5A 1
1
/
4
inch
220V or 240V T3A 5mm x 20mm
After replacing the fuse, switch the amplifier on and check
whether it operates normally. If the fuse blows again, switch the
unit off immediately, disconnect it from the mains supply and get
in touch with your VIOLA dealer, national distributor or VIOLA
directly for technical support. Contact details for VIOLA are given
in the GETTING IN TOUCH section of this manual.
TROUBLE SHOOTING
Most problems may be resolved by following the steps below. If these fail, please
contact your VIOLA dealer, national distributor or VIOLA directly.
1. No sound and the power supply front panel LED is not lit.
Check that the power switch on the power supply rear panel is
set to the ON position.
Check that the power lead is inserted all the way into the AC
input receptacle on the power supply rear panel, the other end is
plugged into the AC wall outlet and if applicable, that the wall
outlet socket is switched on.
Check that there is power on the AC wall outlet socket by
connecting another piece of equipment that is known to work to
the socket.
Check the mains fuse as shown in the MAINS FUSE section of
this manual.
2. No sound and the preamplifier front panel LED is not lit.
If the power supply front panel LED is not lit, check the items in
section 1 above.
Check that the DC power cable is fully inserted into the sockets
on the rear of the power supply and the Cadenza.
2. No sound and the preamplifier front panel LED is lit.
Check the entire signal wiring in the system.
Check that all the units feeding the Cadenza are switched on
and that the signal source is playing music.
Check that the input selector and any other relevant switches
are set appropriately.
Check that the signal source is playing.