Installation guide

© 2006 Directed Electronics—all rights reserved
59
3-7 SHORT RUN/TURBO 1/3/5/10 MINUTES: When the and

buttons on the remote control
are pressed simultaneously, the vehicle will start for the programmed short run time. The factory default is
1 minute.
3-8 ACTIVATION PULSE COUNT 1/2: This allows the system to use 1 or 2 pulses to activate the remote
start sequence. The default setting is 2-pulses.
Note: 1 or 2 pulses on the WHITE/BLUE remote start activation input wire as well as the button of
the remote control.
3-9 2
nd
IGNITION/ACCESSORY OUTPUT: This will allow the PINK/WHITE to be used as a 2
nd
ignition or an
accessory. The default is 2
nd
ignition.
3-10 ACCESSORY STATE DURING WAIT-TO-START OFF/ON: This feature will allow the selection of the acces-
sory output to be ON or OFF during wait-to-start.
3-11 2nd STATUS OUTPUT NORMAL/REAR DEFOGGER LATCHED 10-MIN/PULSE: This feature will allow selec-
tion of status output or a rear defogger mode that turns on ten seconds after the vehicle has started if the
vehicle interior temperature is below 55 degrees F. The defogger mode has two selections, latched or pulsed.
Latched mode will only stay on for 10 minutes.
3-12 ANTI-GRIND ON/OFF: With the anti-grind On (default) the ground-when-armed output will be active
during remote start operation. If accessories such as a voice module or window module are added to the
unit, it may be necessary to program this feature off.
3-13 DIESEL TIMER—WAIT-TO-START/15, 30, 45 SECONDS: Default is the “Wait-to-Start” input
control wire, or programmable to ignore the input control wire by a delay of 15, 30, or 45 seconds. This
feature can be also programmed with the Bitwriter® and with a delay from 1 to 90 seconds.
3-14 TIMER MODE—TIMED STARTS/TEMPERATURE STARTS: The system will start every 3-hours until can-
celed by the brake, hood, or neutral safety shut-down wires (a maximum of 6 times). The temperature start
mode will not start the vehicle unless the interior temperature of the vehicle is less than 0 degrees F. The
temperature start mode will exit after 18 hours.
3-15 RUN TIME (TIMER MODE)—12, 3, 6, 9 MINUTES: Selects the time in minutes that the system
will operate the engine until the system "times out". This is the maximum operation period and the system
may be shut down using a shutdown at any time. Using the Bitwriter®, the run time can be programmed
for any duration from 1-16 minutes.