Air Conditioner User Manual

INSTRUCTIO NS MANUA L
MAINTENANCE
REPLACING REFRIGERANT FILTER/DRYER
The VIPER VR-6000 is equipped with two high side refrigerant filters/dryers and a low side
refrigerantfilter/dryer (see figure 14). In order to maintain high qualityrecycled refrigerant:
The low side refrigerant filter/dryer must be changed when the VR-6000 displays the
service alarm [SERV]and the led “REPLACE FILTER” lights up.
NOTE: When recovering new refrigerantas when the machine is first placed in service
this alarm will light abnormally early and may be cleared by press ing the “SEL” key
while turning on the machine.
The high-press ure refrigerant filters/dryers must be replaced after approximately 30
hours ofoperation or150 service jobs.
ATTENTION: Use only Clore Automotive Filters Part No. 315-032-000 (Low )
andPart No.315-035-666 (High).
When changing the high press ure filters it is recommended that you disconnect the liquid
hose from the storage tank (close the hose valve and the liquid tank valve first), and recover
the refrigerant from the machine with another machine through the liquid hose. Then
proceed as described below:
2
3
1
Fig.14:Dryer filters
20