11
5
Hous
ehold 5.25%
Bleach Solution
BLE
ACH
x2
2
1
Remove cartridge(s) and
pour 2 cups of household
bleach solution into the sump
housing(s).
Note: DO NOT use Hydrogen
Peroxide.
6
6
Reinstall sump only to filter
head.
7
Turn on water supply.
Allow water to fill the
chamber.
8
0
30
15
45
30 mins
Turn on the cold water supply
followed by hot water (if
available) until you smell the
bleach.
Close all faucets and allow
bleach to settle in the water
lines for 30 minutes.
9
Press the pressure button to
release the pressure.
10
10
With all faucets closed,
remove sump housing(s)
using sump wrench.
11
1
2
Reinstall the cartridge(s) into
sump housing(s) and connect
to the unit.
Flush all water outlets until
bleach can no longer be
smelled (at least 5 minutes).
1212
Press the pressure button to
purge air and to complete the
disinfection procedure.