Instructions / Assembly

Maintenance
20
Section 5 Maintenance
5.1 Replacing UV Lamp
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Procedure:
WARNING
Always disconnect power before performing any work on the disinfection system.
Always shut-off water flow and release water pressure before servicing.
Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.
Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
NOTICE
Do not use water during replacement of UV lamp.
1
1
1
1
2
Close all faucets and water
supply.
Press the pressure release
button to relieve the pressure
from the cartridges.
2
0
30
15
45
10 mins
Disconnect main power
source and allow the unit to
cool for 10 minutes.
3
1
2
Remove the lamp connector
by pulling the tabs out and
then upwards.
4
2
1
Hold sleeve bolt with one
hand and turn lamp counter-
clockwise and pull the lamp
outside the chamber in
upward direction.
5
1
2
Insert new lamp into the
quartz sleeve and thread into
sleeve bolt until hard stop.
6
Connect the green ground
wire and red strain relief wire
to the chamber using the
grounding screw.
7
Align connection pins with
the lamp connector by
rotating the ring clamp.
Push the lamp connector
down onto the lamp pins and
the ring clamp pins until an
audible click is heard.
Note: Ensure the connector
is engaged on both sides.
8
Reset lamp timer.