4.1 Replacing UV Lamp
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Procedure:
1
Close all faucets and water
supply.
Press the pressure button to
release the pressure from the
cartridges.
2
0
30
15
45
10 mins
Disconnect main power
source and allow the unit to
cool for 10 minutes.
3
1
2
Remove the lamp connector
by pulling the tabs out and
then upwards.
4
2
1
Hold sleeve bolt with one
hand and turn lamp counter-
clockwise and pull the lamp
outside the chamber in
upward direction.
5
1
2
Insert new lamp into the
quartz sleeve and thread into
sleeve bolt until hard stop.
6
Connect the green ground
wire and red strain relief wire
to the chamber using the
grounding screw.
7
Align connection pins with
the lamp connector by
rotating the ring clamp.
Push the lamp connector
down onto the lamp pins and
the ring clamp pins until an
audible click is heard.
Note: Ensure the connector
is engaged on both sides.
8
Restore power.
If new lamp was inserted,
press and hold lamp timer
reset button for 5 seconds.
Display should read .
Open all faucets and water
inlets, then close all faucets
and inspect for any leaks.
NOTICE
Do not use water during replacement of UV lamp.