Section 7 Specifications
IHS12-D4 IHS22-D4 IHS10-D4
Operating Parameters
Maximum operating pressure 100 PSI (689 kPa) 100 PSI (689 kPa) 100 PSI (689 kPa)
Minimum operating pressure 4 PSI (27.5 kPa) 4 PSI (27.5 kPa) 4 PSI (27.5 kPa)
Maximum ambient air temperature 122 ºF (50 ºC) 122 ºF (50 ºC) 122 ºF (50 ºC)
Minimum ambient air temperature 36 ºF (2 ºC) 36 ºF (2 ºC) 36 ºF (2 ºC)
Maximum humidity 95% 95% 95%
Maximum hardness 120 ppm (7 grains per gallon) 120 ppm (7 grains per gallon) 120 ppm (7 grains per gallon)
Maximum iron 0.3 ppm 0.3 ppm 0.3 ppm
Minimum UVT 75% 75% 75%
Flow Rates
Maximum rated flow at dose of 16 mJ/cm
2
** 16 gpm (60 lpm) (3.6 m
3
/hr) 16 gpm (60 lpm) (3.6 m
3
/hr) 16 gpm (60 lpm) (3.6 m
3
/hr)
Maximum rated flow at dose of 30 mJ/cm
2
** 12 gpm (45 lpm) (2.7 m
3
/hr) 12 gpm (45 lpm) (2.7 m
3
/hr) 12 gpm (45 lpm) (2.7 m
3
/hr)
Maximum rated flow at dose of 40 mJ/cm
2
** 9 gpm (34 lpm) (2 m
3
/hr) 9 gpm (34 lpm) (2 m
3
/hr) 9 gpm (34 lpm) (2 m
3
/hr)
Electrical
Voltage
2
100-240V AC 100-240V AC 100-240V AC
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
Max. current 1 Amp 1 Amp 1 Amp
Max. power consumption 50 Watts 50 Watts 50 Watts
Lamp power 40 Watts 40 Watts 40 Watts
Other
UV Chamber Material 304 SST 304 SST 304 SST
Inlet/Outlet
3
3/4” NPT 3/4” NPT 3/4” NPT
Other
Rated service life of lamp 1 year 1 year 1 year
UV System Certification
1
The max flow rate is determined by the carbon filter.
**
Flow rates shown are at 95% UVT.
2
Units ending in "/2" are for 230V applications.
3
Units ending in "/2B" have BSPT connections.