Instructions / Assembly
General Information
6
2.1 Dimensions and Layout
Figure 2 System - Dimension and Layout
Item Description Function
1 Main water shut-off valve Allows for sampling of raw water.
2 Shut-off Valve Allows for ease of maintenance of whole home UV disinfection system.
3 Bypass shut-off valve
Bypass line and valve are optional. Intended to provide emergency water supply in the
event that the UV system is unavailable.
4 Shut-off valve Allows for ease of maintenance of whole home UV disinfection system.
5 Whole Home System Provides filtration and disinfection of the water.
6 Controller
Powers and controls the UV lamp. Provides human interface, displaying information and
allowing control inputs (such as muting the audible alarm).
7 Power source
Provides power to the controller. For safety reasons the outlet must be protected by a
Ground Fault Circuit Interrupter (GFCI).
Note: To protect the controller, a UL1449 certified (or equivalent) transient voltage surge
suppressor is required.
Main Water
Shut O
Optional By-Pass Assembly
Hot water pipe
Cold water pipe
1
2
4
7
16” Clearance for
lamp removal
6
3
MIN 4” from bottom of unit
for clearance for filter changes
25.5” Overall Length
Optional
Water
Softener
5