Instructions / Assembly
Installation
7
Section 3 Installation
3.1 Installing UV System
Prerequisites:
• Deter
mine appropriate indoor location of the controller and chamber, refer to Section 2.1.
• M
ake sure that the controller is installed higher than the chamber and away from all water sources.
• Ensu
re adequate clearance above chamber to allow for removal of the lamp and sleeve.
• Make s
ure to turn off the main water supply.
• Ma
ke all necessary plumbing connections refer to Section 2.1.
Procedure:
1
• Install the UV system on the
wall using lag bolts (not
supplied). Mounting holes are
located in the metal bracket.
2
• Slide controller onto mounting
bracket.
3
• Insert the reference card
between controller and
mounting bracket.
4
• Connect power cord to
controller.
• DO NOT connect the power
cord to the GFCI outlet at this
time.
5
• Place O-ring on the sleeve as
shown. Insert the sleeve into
the chamber as shown in
step 6.
6
• Ensure quartz sleeve is
properly centered in the
chamber.
7
2
1
• Place sleeve bolt onto the
quartz sleeve, carefully push
down and hand tighten onto
chamber.
8
2
1
• Insert lamp into the quartz
sleeve and thread into sleeve
bolt until hard stop.
CAUTION
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely
fastened to ground stud on UV chamber.