Section 6 Troubleshooting
Symptom Possible Cause Possible Solution
No power
GFCI and/or breaker tripped Reset GFCI and/or breaker
Transient voltage surge suppressor (TVSS) damaged Replace TVSS
Controller damaged Replace controller and use a TVSS
GFCI or breaker repeatedly
trips
Connection between lamp and lamp plug is wet
Clean and dry lamp pins and lamp plug, check unit for leaks
or condensation
Short-circuit in the electrical assembly Replace controller
Leak at inlet or outlet Threaded pipe fittings are leaking Clean threads, reseal with Teflon tape and retighten
Leak detected from area of UV
chamber
Condensation of moist air on cold chamber (slow
accumulation)
Control humidity or relocate unit
O-ring damaged, deteriorated or incorrectly installed Inspect and replace if deteriorated
Lamp/sleeve assembly not properly installed (too tight or not
tight enough)
Tighten assembly hand-tight
Alarm Refer to
Section 5.1. Refer to Section 5.1.
System is operating but water
tests reveal bacterial
contamination
Equipment downstream of UV system is acting as a breeding
ground for pathogens
Ensure UV is the last piece of treatment equipment
Pathogens are residing in the distribution lines post-UV
Ensure all distribution lines have been disinfected with
chlorine. Refer to
Section 3.2.
Recontamination from pipe dead-ends
Remove any pipe dead-ends and flush with chlorine. Refer to
Section 3.2.
Lamp timer does not read
anything
Unit is unplugged Plug unit into AC power outlet
No power at AC power outlet Replace fuse or reset breaker
Power cord is damaged Replace power cord
Power surge caused damage to electrical assembly Replace controller and use a surge protector (TVSS)
Leak detected at filters
O-ring damaged, deteriorated or incorrectly installed
Remove the sump, wipe the O-ring and threads clean. ensure
the O-ring is fitted properly, then reinstall
Filter cartridge not centered
Remove sump, check for cartridge damage, re-assemble
ensuring cartridge is centered